Generate the required ordering code as follows:  e.g. 4M300-BA 

 

 

 

 

4M300 

 

 

 

   TEST BLOCK  (SOCKET) 

 

AUXILIARY SUPPLY ISOLATING LINK

 

A    Not required 

(Isolation Plug not supplied) 

Required 

(Test Block supplied with Isolation Plug) 

 

CASE LENGTH

   (Match to 4M320 case length) 

A    Short 

Default 

Long 

 

 
 
 

Ordering Information 

 

 
 

Generate the required ordering code as follows:  e.g. 4M320-BA 

 

 

 

 

4M320 

 

 

 

   TEST PLUG 

 

CT SHORTING LINKS

 

A    Manual 

(External links to be fitted by operator) 

Automatic 

(Internal links fitted between terminals 

 

 

 21, 23, 25 & 27) 

 

CASE LENGTH

   (Match to 4M300 case length) 

A    Short 

Default 

Long 

 

 

 

TYICAL APPLICATION OF 4M300 TEST BLOCK & 4M320 TEST PLUG 

4M300 Test Block

(REAR VIEW)

Live side

sockets

YELLOW

BLACK

Equipment

side sockets

*

*

Apply secondary injection test signals 

Trip & alarm

contacts or

VT connections

 as required

Relay scheme

DC auxiliary

Protection scheme

1

3

5

7

9

11

13

15

17

19

21

23

25

27

2

4

6

8

10

12

14

16

18

20

22

24

26

28

S2

S2

S2

P1

P2

S1

S1

S1

A

B

C

Figure 8:  Typical use of 4M300 Test Block & 4M320 Test Plug

   4M300-A Terminals 13/14 connected as per other positions

   4M300-B Terminals 13/14 open circuit when Isolation Plug removed

Phase A 

Phase B 

Phase C 

E/F

DC

auxiliary

4M320-A   Manual

4M320-B   Automatic

CT shorting links:

Heavy

duty

current

injection

sockets 

4M320 Test Plug

(FRONT VIEW)

Fit external

links 13-14

& 15-16 if

station DC

auxiliary

is required

during

testing

1

5

9

17

21

25

3

7

11

19

27

23

2

6

10

14

18

4

8

12

16

20

24

26

28

 

 

Summary of Contents for 4M300

Page 1: ...may be used to short CT inputs connect test equipment Equipment under test need only be removed for servicing if problems are detected Technical Bulletin 4M300 Test Block System Figure 1 4M320 A Test Plug Description Made in Australia The Test Block type 4M300 comprises fourteen 14 test circuits each of which is connected to a separate pair of terminals at the rear of the case During the normal op...

Page 2: ...om the protection relay or scheme thereby avoiding dangerously high voltages The continuity of the shorting plug wire links their state of insulation should be checked prior to into the 4M300 test block CT SHORTING AUTOMATIC Internal The 4M320 may be ordered with internal CT shorting links fitted to pre designated positions as follows 4M320 B Internal links between terminals 21 23 25 27 Refer figu...

Page 3: ...orting engaged Circuit isolating bar engaged Equipment side circuits isolated from live side circuits WITHDRAW DC AUXILIARY ISOLATION PLUG 4M300 B model only DC auxiliary supply link between terminals 13 14 is removed Step 1 DC AUXILIARY SUPPLY ISOLATION Step 2 AUTOMATIC CT SHORTING Step 3 CIRCUIT ISOLATION Auxiliary supply isolated 4M300 B CT shorting links engaged INSERT 4M320 B TEST PLUG Automa...

Page 4: ...on TEST LEAD PLUGS Two types of shrouded plug are employed on each test lead as depicted in figure 4 5 Single Plug The single plug is the most compact may be plugged into any test socket Dual Plug The dual or piggy back plug is larger should be plugged into the test sockets on the outside edge of the 4M320 The lead emerging from the dual plug should face out from center of the 4M430 to ensure adeq...

Page 5: ...4M320 TEST PLUG 28 test sockets suitable for 4mm banana plugs Securing screws to retain the Test Plug during testing operations CURRENT RATINGS All CT circuits terminals 20A continuous Terminal 1 to 28 400A 1s VOLTAGE RATINGS All circuits terminals 600V AC continuous 320V DC continuous System auxiliary voltage 40V DC minimum CASE TYPE 2M28 Size 2 28 terminals COMPLIANCE STANDARDS IEC 60068 2 1 600...

Page 6: ...NGTH Match to 4M300 case length A Short Default B Long TYICAL APPLICATION OF 4M300 TEST BLOCK 4M320 TEST PLUG 4M300 Test Block REAR VIEW Live side sockets YELLOW BLACK Equipment side sockets Apply secondary injection test signals Trip alarm contacts or VT connections as required Relay scheme DC auxiliary Protection scheme 1 3 5 7 9 11 13 15 17 19 21 23 25 27 2 4 6 8 10 12 14 16 18 20 22 24 26 28 S...

Reviews: