5. Installing the TCO-HDSP

 

 

Before installing the TCO card, please make sure the computer is switched off and the 
power cable is disconnected from the mains supply.

 

 

1. 

Disconnect the power cord and all other cables from the computer. 

 

2. 

Remove the computer's housing. Further information on how to do this can be obtained 

from your computer´s instruction manual. 

 

3. 

Before removing the TCO from its protective bag, discharge any static in your body by 

touching the metal chassis of the PC. 

 

4. 

Connect the TCO with the PCI card using the supplied flat ribbon cable. For this, plug one 

end of the cable into the matching connector of the PCI card. On the 

AES-32

 the connector 

is labeled 

Synchronizer Board

, on the 

9632

 the TCO replaces the 

Wordclock Module

Plug the other end into the connector X101 on the TCO. 

 

5. 

Insert the TCO into a free PCI slot and fasten the screw. The TCO needs no slot on the 

motherboard, but includes a stabilizing edge, which fits in both PCI and ISA slots. 

 

6. 

Insert the PCI card firmly into a free PCI slot, press and fasten the screw. 

 

7. 

Replace the computer's housing. 

 

8. 

Reconnect all cables including the power cord. 

 
 

6. Installing the TCO-FF

 

 
To install the TCO the Fireface 800 must be opened. If you feel unsecure to do so please con-
sult a technician and let him show you how to do it. Else please follow the instructions below 
step by step. 

 

Before installing the TCO, please make sure the Fireface 800 is switched off and the power 
cable is disconnected from the mains supply.

 

 

1.

 Disconnect the power cord and all other cables from the Fireface 800. 

 
2.

 Loosen and remove both rack ears (two screws each). 

 
3.

 Use a screwdriver (Phillips 1) to remove the 3 screws on the cover near the back panel, and 

2 screws on each side of the Fireface 800, so that the cover can be taken off by sliding it to the 
rear. 

 
4.

 Remove the TCO spare plate within the rear panel (2 screws). 

 

5. 

Before removing the TCO from its protective bag, discharge any static in your body by touch-

ing the metal chassis of the Fireface. 
 

6.

 Slide the TCO into the rear panel's hole from the inside. Watch the correct position, so that 

both screws found in the PCB of the TCO do not press on the TRS jacks, but are placed in-
between those. 
 

7.

 Fasten the TCO with the two black self-tapping screws from the TCO screw set. Do not use 

the screws of the spare plate, as these are thread screws.

 

 

 

Summary of Contents for TCO FF

Page 1: ...User s Guide TCO HDSP FF Time Code Option for HDSP PCI Fireface 800 LTC SMPTE Reader and Generator Video to Word Clock Converter Low Jitter Word Clock Regeneration...

Page 2: ...Package Contents 3 3 Hardware Requirements 3 4 Technical Specifications 4 1 TCO FF 4 4 2 TCO HDSP 4 5 Installing the TCO HDSP 5 6 Installing the TCO FF 5 7 Operation and Usage 7 1 TCO FF 7 7 2 TCO HDS...

Page 3: ...e following TCO FF TCO board with fixed ribbon cable 1 set of screws User s guide TCO HDSP TCO 1 ribbon cable User s guide 3 Hardware Requirements The TCOs can be operated with the following hardware...

Page 4: ...and NTSC Word Clock In Video In BNC switchable termination 75 Ohm Transformer coupled galvanically isolated input Not affected by DC offsets within the network Signal Adaptation Circuit signal refres...

Page 5: ...e computer s housing 8 Reconnect all cables including the power cord 6 Installing the TCO FF To install the TCO the Fireface 800 must be opened If you feel unsecure to do so please con sult a technici...

Page 6: ...are ready to re assemble the Fireface 9 Check that the safety earth wire yellow green is still connected to the cover Then put the cover on and slide it into the aluminum front panel of the Fireface 8...

Page 7: ...d For synchronization to a video or LTC signal choose Clock Mode AutoSync and TCO as Pre ferred Sync Ref on the main page of the settings dialog All further settings are done on the TCO page Sync Sour...

Page 8: ...ings are done on the TCO page Sync Source Input select switch for the inputs LTC video and word clock Lock is dispayed as soon as the TCO is able to synchronize on an input signal Also at the bracket...

Page 9: ...ut the incom ing signal LTC In The time values read from the LTC signal These values are passed unchanged to the application Input State An LTC input signal detection as valid valid is followed by the...

Page 10: ...Leipziger Strasse 32 D 09648 Mittweida Trademarks All trademarks registered or otherwise are the property of their respective owners RME Ham merfall SyncAlign und SyncCheck sind eingetragene Marken v...

Page 11: ...icular installation If this equipment does cause harmful interference to radio or television reception which can be de termined by turning the equipment off and on the user is encouraged to try to cor...

Page 12: ...Bedienungsanleitung TCO 12...

Reviews: