46
User's Guide Fireface UFX+
© RME
21.4 MIDI
Fireface UFX+ offers two MIDI I/O via four 5-pin DIN sockets. The MIDI ports are added to the
system by the driver. Using MIDI capable software, these ports can be accessed under the
name
UFX+ MIDI Port
.
All RME MADI devices support the invisible transmission of MIDI via MADI. MIDI data can be
transmitted from/to other RME devices with MADI ports, without any additional line or cabling
between computer (MADI interface) and external units. These ports can be accessed under the
name
UFX+ MADI Optical
and
UFX+ MADI coaxial
or
UFX+ MIDI Port 3 and 4
.
The MIDI ports support multi-client operation. A MIDI input signal can be received from several
programs at the same time. Even the MIDI output can be used by multiple programs simultane-
ously. However, due to the limited bandwidth of MIDI, this kind of application will often show
various problems.
Note: The MIDI input LEDs display any kind of MIDI activity, including MIDI Clock, MTC and
Active Sensing. The latter is sent by most keyboards every 0.3 seconds.
22. Word Clock
22.1 Word Clock Input and Output
SteadyClock
guarantees an excellent performance in all clock modes. Based on the highly effi-
cient jitter suppression, the Fireface refreshes and cleans up any clock signal, and provides it
as reference clock at the BNC output (see chapter 39.8).
Input
The Fireface's word clock input is active when
Clock Source
in the Settings dialog has been
switched to
Word
, and a valid word clock signal is present. The signal at the BNC input can be
Single, Double or Quad Speed, the Fireface UFX+ automatically adapts to it. As soon as a valid
signal is detected, the WC LED is lit, and the Settings dialog shows either Lock or Sync (see
chapter 39.1).
Thanks to RME's
Signal Adaptation Circuit
, the word clock input still works correctly even with
heavily mis-shaped, dc-prone, too small or overshoot-prone signals. Thanks to automatic signal
centering, 300 mV (0.3V) input level is sufficient in principle. An additional hysteresis reduces
sensitivity to 1.0 V, so that over- and undershoots and high frequency disturbances don't cause
a wrong trigger.
The Fireface UFX+ word clock input can be not terminated or internally terminated (75 Ohms).
The state is comfortably selected within the Settings dialog. To terminate the input check the
option
Word Clock In Term.
under
Input Options
.
Output
The word clock output of the Fireface is constantly active, providing
the current sample frequency as word clock signal. As a result, in
Master mode the provided word clock is defined by the currently used
software. In Slave mode the provided frequency is identical to the one
present at the currently chosen clock input. When the current clock
signal fails, the Fireface UFX+ switches to Master mode and adjusts
itself to the next, best matching frequency (44.1 kHz, 48 kHz etc.).
Selecting
Single Speed
in the Settings dialog causes the output signal to always stay within the
range of 32 kHz to 48 kHz. So at 96 kHz and 192 kHz sample rate, the output word clock is 48
kHz.
Summary of Contents for Fireface UFX+
Page 7: ...User s Guide Fireface UFX RME 7 User s Guide Fireface UFX General...
Page 12: ...12 User s Guide Fireface UFX RME...
Page 13: ...User s Guide Fireface UFX RME 13 User s Guide Fireface UFX Installation and Operation Windows...
Page 31: ...User s Guide Fireface UFX RME 31 User s Guide Fireface UFX Installation and Operation Mac OS X...
Page 41: ...User s Guide Fireface UFX RME 41 User s Guide Fireface UFX Inputs and Outputs...
Page 49: ...User s Guide Fireface UFX RME 49 User s Guide Fireface UFX Stand Alone Operation...
Page 52: ...52 User s Guide Fireface UFX RME...
Page 53: ...User s Guide Fireface UFX RME 53 User s Guide Fireface UFX TotalMix FX...
Page 55: ...User s Guide Fireface UFX RME 55...
Page 91: ...User s Guide Fireface UFX RME 91 User s Guide Fireface UFX Class Compliant Mode...
Page 97: ...User s Guide Fireface UFX RME 97 User s Guide Fireface UFX DURec Direct USB Recording...
Page 104: ...104 User s Guide Fireface UFX RME...
Page 105: ...User s Guide Fireface UFX RME 105 User s Guide Fireface UFX Technical Reference...
Page 118: ...118 User s Guide Fireface UFX RME 40 Diagrams 40 1 Block Diagram Fireface UFX...
Page 120: ...120 User s Guide Fireface UFX RME...
Page 121: ...User s Guide Fireface UFX RME 121 User s Guide Fireface UFX Miscellaneous...