background image

 

 

User’s Guide HDSP System Digiface 

© RME

 

29

 

 

20. Warranty

 

 
Each individual Hammerfall DSP undergoes comprehensive quality control and a complete test 
in a PC environment at RME before shipping. This may cause very slight signs of wear (if it 
looks like it was used one time before - it was). The usage of high grade components allows us 
to offer a full two year warranty. We accept a copy of the sales receipt as valid warranty 
legitimation. 
 
RME’s replacement service within this period is handled by the retailer. If you suspect that your 
card is faulty, please contact your local retailer. The warranty does not cover damage caused 
by improper installation or maltreatment - replacement or repair in such cases can only be 
carried out at the owner’s expense. 
 
RME does not accept claims for damages of any kind, especially consequential damage. 
Liability is limited to the value of the Hammerfall DSP. The general terms of business drawn up 
by Synthax OHG apply at all times. 
 
 

21. Appendix

 

 
RME news, driver updates and further product information are available on our website: 
 
http://www.rme-audio.com 
 
If you prefer to read the information off-line, you can load a complete copy of the RME website 
from the RME Driver CD (in the 

\rmeaudio.web

 directory) into your browser. 

 
 
 

Trademarks

 

 
All trademarks, registered or otherwise, are the property of their respective owners. RME, 
DIGI96, SyncAlign, SyncCheck, ZLM and Hammerfall are registered trademarks of RME 
Intelligent Audio Solutions. DIGICheck, , TotalMix and TMS are trademarks of RME Intelligent 
Audio Solutions. Alesis and ADAT are registered trademarks of Alesis Corp. ADAT optical is a 
trademark of Alesis Corp. Microsoft, Windows, Windows 98/2000/XP are registered trademarks 
or trademarks of Microsoft Corp. Apple and MacOS are registered trademarks of Apple 
Computer Inc. Steinberg, Cubase and VST are registered trademarks of Steinberg Media 
Technologies AG. ASIO is a trademark of Steinberg Media Technologies AG. emagic and 
Logic Audio are registered trademarks of emagic Soft- und Hardware GmbH. Pentium is a 
registered trademark of Intel Corp. 
 

Copyright 

 Matthias Carstens, 3/2002. Version 1.4 

Current driver version: 2.10 

 

Although the contents of this User’s Guide have been thoroughly checked for errors, RME can not guarantee that it is correct 
throughout. RME does not accept responsibility for any misleading or incorrect information within this guide. Lending or 
copying any part of the guide or the RME Driver CD, or any commercial exploitation of these media without express written 
permission from RME Intelligent Audio Solutions is prohibited. RME reserves the right to change specifications at any time 
without notice. 

Summary of Contents for DIGIFACE

Page 1: ...Hammerfall DSP System Digiface PCI Busmaster Digital I O System PCI and CardBus Interface 2 24 Channels Stereo ADAT Interface 24 Bit 96 kHz Analog Stereo Monitor ADAT Sync In TotalMix 24 Bit 96 kHz S...

Page 2: ...ables and Termination 14 10 3 General Operation 15 11 Using more than one Hammerfall DSP 15 12 Special Characteristics of the SPDIF Output 15 13 Operation under ASIO 2 0 13 1 General 16 13 2 Performan...

Page 3: ...functions directly in hardware and not in the driver i e the CPU 2 Package Contents Please check that your Hammerfall DSP Systems package contains each of the following PCI Interface PCI card HDSP Qu...

Page 4: ...Line headphone output separate output for independent submix DIGICheck DSP Level meter in hardware peak and RMS calculation TotalMix 1456 channel mixer with 40 bit internal resolution 5 Technical Spe...

Page 5: ...he computer s housing Further information on how to do this can be obtained from your computer s instruction manual 3 Important Before removing the card from its protective bag discharge any static in...

Page 6: ...iles The driver installation is done manually in 5 steps 1 Drag the file Hammerfall DSP Driver from into System folder into the System folder It will be installed automatically into the Extension fold...

Page 7: ...mixer of the Digiface TotalMix requires Carbon Library 1 1 which is part of the operating system since MacOS 9 1 After installation of Carbon Library 1 1 TotalMix can even be run on older systems dow...

Page 8: ...iface has the first MIDI input and output the power supply connector AUX only needed with CardBus operation and all digital inputs and outputs ADAT I O TOSLINK 1 to 3 The ADAT1 I O can also be used fo...

Page 9: ...rrent configuration the board itself and all connected external equipment If no sample frequency is recognized it will read No Lock With this configuring any suitable audio application for digital rec...

Page 10: ...ng the dialog is not required However settings should not be changed during playback or record if it can be avoided as this can cause unwanted noises Also please note that even in Stop mode several pr...

Page 11: ...he settings Professional Emphasis and Non Audio please refer to chapter 12 Clock Mode The card can be configured to use its internal clock Master or the clock source pre defined via Pref Sync Ref Auto...

Page 12: ...ster If the HDSP s clock mode is set to Master all other devices must be set to Slave All the ADAT optical inputs in the Hammerfall DSP as well as the SPDIF input will work simultaneously Because ther...

Page 13: ...requency of the mixing desk but not identical Remedy To drive the ADAT recorder from its digital input set it to slave mode DIG and connect the input to the HDSP s ADAT3 output The Hammerfall DSP is a...

Page 14: ...commend using off the shelf BNC cables to connect all devices as this type of cable is used for most computer networks You will find all the necessary components T adapters terminators cables in most...

Page 15: ...d header and creates a totally new one for the output signal Note that in record or monitor modes set emphasis bits will disappear Recordings originally done with emphasis should always be played back...

Page 16: ...the device ASIO Hammerfall DSP 96 kHz has to be chosen When the sample frequency is set to 88 2 or 96 kHz this driver operates all the ADAT optical inputs and outputs in Sample Split mode so the numb...

Page 17: ...Cubase s transport panel will open the Synchronization dialog Select ASIO 2 0 as the timecode base under Sync Source confirm the dialog with OK then activate Sync mode by single clicking on the Sync...

Page 18: ...he Surface The visible design of the mixer is mainly determined by the architecture of the HDSP system Upper row hardware inputs The level shown is that of the input signal i e Fader independent Per f...

Page 19: ...two channels It is therefore helpful to be able to make the routing settings for two channels at once Press the Ctrl key and click into the routing window of Out 3 with the key pressed The routing lis...

Page 20: ...lo the Mute buttons for Out 1 to Out 4 light up as before And if you chose Solo for a channel of this Mute group mute will be deactivated but immediately activated again if Solo is released 14 5 Hotke...

Page 21: ...ous view The mixer can also be made smaller horizontally and scrolled TotalMix can be made substantially smaller and space saving on the desktop screen if you have to have to monitor or set only a few...

Page 22: ...All inputs maximum attenuation m a All playback channels 0 dB routet to the same output All output channels 0 dB phones 6 dB Submix of all inputs and outputs to the analog output Phones with input fad...

Page 23: ...nal shows both 0 dBFS Peak and RMS This setting also yields directly readable signal to noise values while other applications like WaveLab will show a value 3 dB better than actual because the referen...

Page 24: ...switches off power the red Host LED begins to blink The card can now be pulled out of the PCMCIA slot The Hammerfall DSP System was tested thoroughly on several notebooks by RME We did not find any co...

Page 25: ...nnels don t seem to work S PDIF output has been switched to ADAT1 This means that the first ADAT output device and therefore the first 8 channels in the ASIO application are no longer available All ch...

Page 26: ...vice The following symptoms are typical for PCI related problems When booting the control panels are displayed too big or spread across the whole screen Software or OS crash as soon as the card is use...

Page 27: ...wlessly even with a cable length of up to 50ft 15 m 36081 RME Firewire cable for CardBus 15 6M 5 m 16 4 ft Special cable 15 pin close Lan coded to 6 pin male for RME CardBus card 36003 Optical cable T...

Page 28: ...ivers Configuring Logic Samplitude and Cubase for the DIGI32 96 series Configuring Cakewalk and SAWPlus32 for the DIGI32 96 series Step by step instructions DIGICheck Analysis tests and measurements w...

Page 29: ...rectory into your browser Trademarks All trademarks registered or otherwise are the property of their respective owners RME DIGI96 SyncAlign SyncCheck ZLM and Hammerfall are registered trademarks of R...

Page 30: ...User s Guide HDSP System Digiface RME 30 22 Diagrams 22 1 Block Diagram Digiface...

Page 31: ...ths in ASIO double speed mode 88 2 96 kHz The devices available under ASIO have been implemented according to the hardware Signal routing is identical for record and playback Device The device name in...

Page 32: ...w inside the TotalMix mixer of the Digiface It shall clarify the following function The input signal of the hardware ADAT SPDIF In is always directly fed through to the recording software At the same...

Page 33: ...ies and if not installed and used according to the instructions in the User s Guide may cause interference harmful to the operation of other electronic devices Compliance with FCC regulations does not...

Reviews: