background image

 

www.rkiinstruments.com

82-5222 

24 VDC Pneumatic ESTOP

Operator’s Manual

Part Number: 71-0571

Revision: P1

Released: 8/13/21

Summary of Contents for 82-5222

Page 1: ...www rkiinstruments com 82 5222 24 VDC Pneumatic ESTOP Operator s Manual Part Number 71 0571 Revision P1 Released 8 13 21...

Page 2: ...nsportation costs or contingent expenses incurred without our prior approval THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATIONS EXPRESSED OR IMPLIED AND ALL OTHER O...

Page 3: ...4 Specifications 4 Description 5 External Description 5 Internal Description 6 Installation 7 Mounting 7 Factory Wiring 9 Field Wiring 10 Making Tubing Connections 12 Start Up 13 Operation 13 Normal O...

Page 4: ...door is pushed the internal solenoid valve de energizes and the pneumatic line between the 82 5222 and the user supplied pneumatic device depressurizes through the vent port A set of remote relay con...

Page 5: ...installation and mounting Four mounting feet are attached to the back of the housing one at each corner The mounting feet are used to install the housing to a wall One conduit hub on the bottom of the...

Page 6: ...is green the pneumatic line between the 82 5222 and the connected pneumatic device is pressurized When the light is red the In port is closed and the pneumatic line between the 82 5222 and the connec...

Page 7: ...ring Terminal Strip allows for a set of remote relay contacts to be wired into the system as an additional control over the solenoid valve A factory installed jumper should be left installed if remote...

Page 8: ...8 82 5222 4 Insert 3 16 in screws through the mounting slots to secure the housing to the mounting surface Figure 3 Outline Mounting Dimensions 7 19 8 09 6 04 23 x 3 slot 4X 11 41 18 82...

Page 9: ...connections should not need adjustment Figure 4 Factory Wiring 1 5 Relay NC NO 4 8 9 NO NC Black Black C Red Red IN PUT PO WER 24 VDC _ 12 Red C Red Green Yellow Red Red Green 1 N C 2 Red Not Used Sta...

Page 10: ...gured as normally energized 6 Remove the jumper from the Field Wiring Terminal Strip NOTE If you are not connecting a remote relay contact to the 82 5222 the jumper must stay installed 7 Guide a 2 con...

Page 11: ...lose the housing door NOTE If remote relay contacts are not wired to the Field W iring Terminal Strip leave the jumper installed 24 VDC Power Source _ Field Wiring Terminal Strip _ INPUT POWER 24 VDC...

Page 12: ...ach of the 82 5222 s compression fittings hold the fitting still using a 5 8 inch open end wrench or an adjustable wrench and firmly tighten the nut with a 9 16 inch open end wrench or an adjustable w...

Page 13: ...on Normal Operation During normal operation the stack light is green the solenoid valve is energized and the pneumatic line between the 82 5222 and the connected pneumatic device is pressurized Alarms...

Page 14: ...with a zip tie Figure 6 Fuse Location 4 Cut the zip tie to access the fuse holder 5 Unscrew the two halves of the fuse holder 6 Remove the old fuse 7 Install the new fuse 8 Screw the two halves of the...

Page 15: ...lists replacement parts and accessories for the 82 5222 Table 2 Parts List Part Number Description 43 4143RK Fuse 5 mm x 20 mm 250V 1A slow blow 51 0210 Stack light red green steady 71 0571 82 5222 Op...

Reviews: