RKI Instruments 49-0121-10 Operator'S Manual Download Page 7

 

49-0121-10 Power Supply • 7

Wiring the Power Supply

1. Turn off or unplug power to the AC power source.

2. Open the power supply housing door.
3. Route three wires in conduit or a three wire cable with wires from the AC power source to the 

power supply’s conduit hub. 

4. Connect the three wires to the AC input terminals on the power supply as shown below using 

either plain wire or #6 lugs.

 Figure 4: Wiring AC Power to the Power Supply

AC Power

Source

N G

L

L N

-V -V +V +V

Note: T he ground terminal

has a factory-installed wire 

connecting it to the 

conduit hub's ground stud.

Summary of Contents for 49-0121-10

Page 1: ...www rkiinstruments com 49 0121 10 AC DC Power Supply Operator s Manual Part Number 71 0568 Revision P1 Released 7 19 21...

Page 2: ...t costs local repair costs transportation costs or contingent expenses incurred without our prior approval THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATIONS EXPRES...

Page 3: ...ply Specifications Table 1 lists specifications for the power supply Table 1 Specifications Construction housing NEMA 4X Power Input 100 240 VAC 2 5 A Power Output 24 VDC 4 5 A Operating Temperature 4...

Page 4: ...24 VDC It is normally used to power peripheral devices such as horns and strobes The power supply assembly consists of a power supply in a NEMA 4X housing with a conduit hub on the bottom for wiring...

Page 5: ...g 24 VDC Consider the following when you select the mounting site Select a site where the power supply is not likely to be bumped or disturbed Make sure there is sufficient room to perform wiring proc...

Page 6: ...Supply 3 Insert 3 16 inch screws through the slots in the mounting feet at each corner of the housing to secure the housing to the mounting surface Figure 3 Outline Mounting Dimensions 4 8 5 6 21 x 33...

Page 7: ...ire cable with wires from the AC power source to the power supply s conduit hub 4 Connect the three wires to the AC input terminals on the power supply as shown below using either plain wire or 6 lugs...

Page 8: ...s conduit hub 6 Connect the two wires to the DC output terminals on the power supply as shown below using either plain wire or 6 lugs Figure 5 Wiring 24 VDC Devices to the Power Supply 7 Turn on the...

Reviews: