2 • 35-3010RKA-03 Sample-Draw Detector
Description
This section describes the components of the
35-3010RKA-03 sample-draw detector.
The
sample-draw detector consists of the housing, flow system, and detection system.
Figure 1: Sample-Draw Detector Component Location
Housing
The sample-draw detector’s fiberglass housing is weather- and corrosion-resistant. It is
suitable for installation where general purpose equipment is in use. The housing door is
hinged on the left side and is secured by two latches on the right side.
Four mounting feet are attached to the back of the housing (one at each corner). Use the
mounting feet to install the housing to a vertical surface. Use the two conduit hubs on the
bottom of the housing to make wiring connections.
An aluminum subpanel is mounted to the interior of the housing. The sample-draw
detector’s internal components are mounted to the subpanel.
+
2 4V
BAT T
+
OX Y
W
G
F B
4 /2 0
TOX IC
TP
+
ZE RO
OXY
T OXIC
TP
-
BK
RD
S PAN
Hydrophobic
Filter (AcroPak)
Flow
Block
Amp 1
Pump
Preamp
Circuit
Board
H2S Sensor
Dummy Plug
LEL Transmitter
Charcoal Filter
Oxygen Sensor
CO Sensor
Combustible
Sensor
Amp 2
Inlet Fitting For 1/4" OD
Rigid Tubing
3/4 Conduit Hub, 2X
Exhaust Fitting For 1/4"
OD Rigid Tubing
Main Circuit Board
Oxygen Transmitter
Reset Switch