![RKC INSTRUMENT THW-3 Series Quick Start Manual Download Page 8](http://html1.mh-extra.com/html/rkc-instrument/thw-3-series/thw-3-series_quick-start-manual_1466633008.webp)
CTHW01E
Accessories
!
THVP-S01
THWP-C01
THWP-T01
20A
30A
45A/60A
80A
100A
THWP-F30
THWP-F40
THWP-F20
THWP-F80
THWP-FA0
Fast-blow fuse
200V
20A
30A
45A/60A
80A
100A
THWP-F32
THWP-F42
THWP-F22
THWP-F82
THWP-FA2
400V
20A
30A
45A/60A
80A
100A
200V
20A
30A
45A/60A
80A
100A
400V
THWP-F31
THWP-F41
THWP-F21
THWP-F81
THWP-FA1
THWP-F33
THWP-F43
THWP-F23
THWP-F83
THWP-FA3
THWP-A01
THWP-A02
THWP-A03
Unit : mm
Unit : mm
•
Prevent metal fragments or load wire scraps from falling inside instrument to avoid electric shock, fire or malfunction.
•
All wiring must be completed before power is turned on to prevent electric shock, fire or incorrect action.
CAUTION
200V : 20A, 30A, 45A, 60A
400V : 20A, 30A, 45A, 60A
200V/400V : 80A,100A
117
73
22
46
Max.47
60
50
31
40
φ
5-4
L1 L2 L3
l
1
l
2
l
3
(Unit : 1 piece)
• Gradient setter, Manual setter, High/Low setter : THVP-S01
Scale plate
Knob
10
20
30
40
50
60
70
80
90
100
0
48
48
13.5 10 10
φ
24
φ
6
M9X0.75
2
φ
2.8
Volume (Resistance:5k
Ω
,B)
10
φ
16.1
φ
14.8
18.7
• Step-down transformer : THVP-T01
* When power supply is 400V type,
Voltage down transformer (For
instrument power supply) is supplied.
* Please refer to the following codes to order accessories.
• Model code
Name
Setter
Model Code
Name
Model Code
Name
Model Code
Name
Model Code
Connector (plug)
Voltage down transformer
Terminal cover
(For main circuit
terminal)
(Unit : 1 piece)
Fast-blow fuse
with fuse break
alarm
•
Before operating this product, read the instruction manual carefully to avoid incorrect operation.
•
This product is intended for use with industrial machines, test and measuring equipment. It is not designed
for use with medical equipment.
•
If it is possible that an accident may occur as a result of the failure of the product or some other
abnormality, an appropriate independent protection device must be installed.
•
When installing this product, avoid the following:
•Direct exposure to sunlight.
• Direct contact with water.
• Corrosive environments.
• Hazardous areas containing explosive or flammable gases.
• Vibration or shock.
• Areas subject to electrical noise caused by inductive interference, static electricity or magnetic fields.
Printed in Japan: FEB.2005 7DOH(P) All Rights Reserved
Safety
Warning
(RIKA KOGYO CO.,LTD)
HEAD OFFICE : 16-6, KUGAHARA 5 CHOME OHTA-KU TOKYO 146-8515 JAPAN
PHONE : 03-3751-9799 ( +81 3 3751 9799 )
Email :
FAX :
03-3751-8585 ( +81 3 3751 8585 )
http://www.rkcinst.com/