![RJG Lynx LE-R-50-REVB Product Manual Download Page 9](http://html.mh-extra.com/html/rjg/lynx-le-r-50-revb/lynx-le-r-50-revb_product-manual_1466484009.webp)
Product Manual | Lynx™ 50-Inch Stroke/Velocity Sensor LE-R-50-REVB
3
INSTALLATION
INSTALLATION OVERVIEW
Read all instructions before installing
hardware and related components. Contact
RJG, Inc. Customer Support for any
questions regarding installation. Follow
all installation instructions, notes, and
cautions.
INSTALLATION SPECIFICATIONS
REQUIREMENTS
Determine a mounting location for the
LE‑R‑50‑REVB; the location must provide
the following:
•
fixed position on injection unit sled
•
a clear, straight, unobstructed cable path
to and from the LE‑R‑50‑REVB body
NOTES
L
The stroke/velocity sensor cable
must enter the cable bushing
straight to eliminate wear on the
cable and prevent erroneous
readings.
CAUTION
a
Screw travel must not exceed
50” (1,27 mm). Failure to comply
will result in inaccurate readings,
personal injury, and damage or
destruction of equipment.
The maximum off‑center degree allowable
is 5°, and is measured as a distance using
the following equation:
Distancemax = 0.087 x Cable Length
For example, if the cable is extended 20”
at 5°, then 0.087 x 20” = 1.74”; 1.74” is the
Distancemax, or maximum height of the
cable as measured from the center.
Summary of Contents for Lynx LE-R-50-REVB
Page 2: ...PRINT DATE REVISION NO 08 24 2021 1 ...
Page 6: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual iv ...
Page 8: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 2 DIMENSIONS ...
Page 14: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 8 ...
Page 16: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 10 ...
Page 20: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 14 ...
Page 21: ......