**Example**
Set mode 1. Temperature unit=℃
2. RTD=PT100
3. T1 no ERROR
4. T2 no ERROR
5. Power74~50%
Set mode MOD
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 09
Bit 08
X
X
X
X
X
X
X
X
Bit 07 Bit 06 Bit 05
Bit 04
Bit 03
Bit 02
Bit 01~ Bit 00
X
X
℉=1
℃=0
PT100=0
PT1K=1
T2 Error=1 T1 Error=1
Power
☆Power Meter is divided into 4 parts 11=100~75% 10=74~50%
01=49~25% 00=24~0%
-10-
Address
Data name
Data size
0000h
T1 Real-Time Data(Hold)
4-Byte
0001h
T1 Max
4-Byte
0002h
T1 Min
4-Byte
0003h
T1 Avg
4-Byte
0004h
T2 Real-Time Data(Hold)
4-Byte
0005h
T2 Max
4-Byte
0006h
T2 Min
4-Byte
0007h
T2 Avg
4-Byte
0008h
First 2-byte = T1-Hi.A
Last 2-byte = T1-Lo.A
4-Byte
0009h
First 2-byte = T2-Hi.A
Last 2-byte = T2-Lo.A
4-Byte
000Ah
Set mode = MOD