Rixen DR-20 series Instruction Manual Download Page 9

 

DR-20 Series specifications 

Model No.

 

DR-20 

DR-20D 

DR-22 

DR-22D 

Measuring 

Range 

Temperature: 

-40~85

 (-40~185

Temperature: -40~+85

 

Humidity: 0~100% RH 

Accuracy 

± 0.5

 (± 0.9

± 0.5

(± 0.9

)/±3% RH 

(at 20%~80%RH, Temp. 25°C±5

Resolution 

0.1

 (0.1

0.1

 (0.1

) / 0.1 %RH 

Memory 

500,000 readings 

250,000 readings per channel 

Display 

DR-20/DR-22: 

1.Red & Green LED Indicator   

DR-20D/DR-22D: 

1.Red & Green LED Indicator   

2.LCD Display (Temperature, Humidity, Max., Min., Hi/Lo Alarm,   

Memory/Battery capacity icon)     

Sensor 

Precision semiconductor sensor 

Sample Rate 

1 second to 24 hours 

Battery Life 

10 years typical at 25

, 15 minute sampling rate, and turn off the   

display/alarm function 

Main 

Features 

Three start modes (Instant start/Button start/Delay start), 

Real-Time, Red/Green LED indicator, Hi/Low Alarm settings, Build-in 

S/N, IP 65 Dust & Splash proof,     

Dimensions 

80X53X16mm 

Weight 

DR-20/22: 54g ; DR-20D/22D: 60g 

Approvals 

RoHS; CE; IP65 

Specifications are subject to change without notice. 

 

Required Accessories 

DFC-201U KIT 

Including USB Docking station, USB Flash Drive for software & 

manual, and USB Computer interface cable 

 

 

Summary of Contents for DR-20 series

Page 1: ...ions in PC DFC 201U Kit includes the following accessories DFC 201U USB Docking station DR USB S USB Flash driver for software DR USB W USB computer interface cable DR 1 05M Software Ver 1 05 and User...

Page 2: ...n endpoint D Display descriptions DR 20D 22D User could turn on off the LCD display function via software Please refer to DFC 201U Software Operation Manual Turn off LCD display function will help use...

Page 3: ...tions please refer to DFC 201U Software Manual 1 Install software DFC 201U Ver1 05 1 1 Connect the USB flash drive to computer 1 2 Double click Setup on the USB contents screen to install DFC 201U sof...

Page 4: ...t Setting the desired start parameters for your application To set start parameters Device Set 1 Sampling Rate 1 second to 24 hours available 2 Temperature Unit or 3 Location Register storage location...

Page 5: ...box show up To avoid occurring any accident which is caused by wrong operation the logger can only be stopped via DFC 201U software As described below 4 Stop Recording Connect the logger to PC via DFC...

Page 6: ...alue on PC synchronous 2 The data logger display type will show up blink symbol if user unplugs the logger while processing real time function There are three ways to deal with it 2 1 Re plug logger t...

Page 7: ...dity Minimum value of Humidity Temp Max Min value display Temperature value Maximum value of Temp Minimum value of Temp Humidity Alarm value display Humidity value Hi A value of Humidity Lo A value of...

Page 8: ...for a while then it will be restored to normal c In order to connect the Logger with computer the optional docking station DFC 201U kit is necessary d Do not press or stab to the breathable waterproo...

Page 9: ...mory Battery capacity icon Sensor Precision semiconductor sensor Sample Rate 1 second to 24 hours Battery Life 10 years typical at 25 15 minute sampling rate and turn off the display alarm function Ma...

Reviews: