Rixen DR-20 series Instruction Manual Download Page 1

 

Temperature/Humidity Data Logger

 DR-20

 series   

Instruction Manual 

Regarding the operation of software and USB Docking station, please refer to 

DFC-201U Software Operation Manual. 

A. Standard Equipment 

Unpack and inspect the contents of the container. Please check all the items listed below 

are included in the carton. 
● DR-20 series Data Logger 
● Instruction Manual 

 
Please note that, DFC-201U (Optional) is a necessary accessory for DR-20 series to 

setting the relative functions in PC. 

DFC-201U Kit includes the following accessories: 
● 

DFC-201U

 USB Docking station 

● 

DR-USB-S

 USB Flash driver for software 

● 

DR-USB-W

 USB computer interface cable   

● 

DR-1.05M

 

Software Ver.1.05 and User’s manual   

 

B. Initial status of 

DR-20D/DR-22D   

The brand new DR-20D / DR-22D can

’t function until user connects it to PC and set the 

related setting. Please press        button which is in the lower left corner of the data logger 

to confirm the logger can work well. 

  Press        button one time to observe the LCD content, it will display for 3 seconds. 

  Press        button continually to scroll through the content as the following flowchart. 

 

DR-20D 

DR-22D 

 

Press         

 

                                                    Press       

 

Press          button continually 

 

 
   

 

Summary of Contents for DR-20 series

Page 1: ...ions in PC DFC 201U Kit includes the following accessories DFC 201U USB Docking station DR USB S USB Flash driver for software DR USB W USB computer interface cable DR 1 05M Software Ver 1 05 and User...

Page 2: ...n endpoint D Display descriptions DR 20D 22D User could turn on off the LCD display function via software Please refer to DFC 201U Software Operation Manual Turn off LCD display function will help use...

Page 3: ...tions please refer to DFC 201U Software Manual 1 Install software DFC 201U Ver1 05 1 1 Connect the USB flash drive to computer 1 2 Double click Setup on the USB contents screen to install DFC 201U sof...

Page 4: ...t Setting the desired start parameters for your application To set start parameters Device Set 1 Sampling Rate 1 second to 24 hours available 2 Temperature Unit or 3 Location Register storage location...

Page 5: ...box show up To avoid occurring any accident which is caused by wrong operation the logger can only be stopped via DFC 201U software As described below 4 Stop Recording Connect the logger to PC via DFC...

Page 6: ...alue on PC synchronous 2 The data logger display type will show up blink symbol if user unplugs the logger while processing real time function There are three ways to deal with it 2 1 Re plug logger t...

Page 7: ...dity Minimum value of Humidity Temp Max Min value display Temperature value Maximum value of Temp Minimum value of Temp Humidity Alarm value display Humidity value Hi A value of Humidity Lo A value of...

Page 8: ...for a while then it will be restored to normal c In order to connect the Logger with computer the optional docking station DFC 201U kit is necessary d Do not press or stab to the breathable waterproo...

Page 9: ...mory Battery capacity icon Sensor Precision semiconductor sensor Sample Rate 1 second to 24 hours Battery Life 10 years typical at 25 15 minute sampling rate and turn off the display alarm function Ma...

Reviews: