74
Upgrade and Maintenance Guide
Replacing SteelHead xx50
Components
Replacing Power Supply Units
Make sure you remove the correct drive.
Figure 3-5. Removing and Replacing the Disk Drives
5.
Open the new disk-drive handle by pressing the orange release button.
6.
Slide in the new disk drive until it mates with the back connectors in the chassis.
7.
Press in the disk-drive handle to close.
The new disk drive runs through a self-test automatically. The disk drive automatically begins proper
operation with the other disk drives. You do not need to set up or configure the new disk drive.
It takes approximately 3 to 4 hours, depending on the system load, to rebuild a new disk drive. The
administrator user receives email when the disk drive has finished rebuilding.
Replacing Power Supply Units
This section describes how to add or replace power supply units for the xx50 appliances. This section
includes the following procedures:
“Replacing Power Supply Units in Interceptor 9350 Appliances” on page 74
Replacing Power Supply Units in Interceptor 9350 Appliances
Interceptor 9350 appliances are equipped with replaceable, hot-swappable power supply units.
Note:
You must use approved power supply units. To order power supply units, contact your sales representative.
Caution:
Use gloves when replacing the power supply units; they can become hot to the touch.