background image

 

RC210309-2014-A 

Caution

!

2. Install IP device 

There are only two mounting types explained in this manual. Refer to the device’s installation guide for more 
various mounting types. 

Semi-Flush Mount 

 

1)

 

Place  the  installation  template  included  in 

the package on the desired installation surface.

 

2) 

Drill holes on the correct spots based on the 

template  paper,  and  insert  the  anchor  blocks 
into the holes.

 

3)

 Open the dome cover. 

*Refer  to  the  caution  below  for  the  details  about 
how to open the cover. 

 

4)

  Connect  necessary  cables  including  a  LAN 

cable and a power cable to the camera.

 

5) 

Hold  the  camera  against  the  surface  where 

the  camera  will  be  mounted  by  matching  the 
alignment holes with the corresponding anchor 
blocks. 

 

6) 

Route  the  cables  through  the  cable  hole  at 

the  bottom  of  the  camera,  and  tighten  the 
anchor blocks with the screws. 

 

7)

  Attach  the  dome  cover  on  the  main  body, 

and lock it up by rotating the dome cover. 

*Refer to the caution below for the details of how to 
attach the dome cover.

 

 

 

When placing the dome cover, look for the carved triangle mark on both dome  cover 
and main body. Both triangles should be aligned together when placing the cover. Once 
the  cover  has  been  placed,  rotate  the  dome  cover  clockwise  for  a  secure  lock.  To 
detach the cover, rotate the cover counterclockwise. Then, align the two triangle marks 
each other, and pull the cover. 

 

 

 
To prevent products from damage, place the camera on a stable and non-vibrating 
surface. If the stability is in doubt, consult safety personnel for reinforcements, and 
then proceed with the installation. 

Caution

!

Summary of Contents for RC2103HD-6611

Page 1: ...cluding the power cable LAN cable and other optional cables To see the correct positions of all connectors refer to the following image below The device is polarity sensitive Incorrect power connection may cause malfunction or damage to the IP device Caution Power Adaptor Connector DC 12V LAN Connector Reset Button microSD SDHC Slot Power Adaptor Connector Located under the plate PAL NTSC Button T...

Page 2: ...ith the corresponding anchor blocks 6 Route the cables through the cable hole at the bottom of the camera and tighten the anchor blocks with the screws 7 Attach the dome cover on the main body and lock it up by rotating the dome cover Refer to the caution below for the details of how to attach the dome cover When placing the dome cover look for the carved triangle mark on both dome cover and main ...

Page 3: ...mbined dome cover to the main body and lock it up by rotating the cover Refer to the caution below for the details about how to lock the cover 7 Tighten the camera s body into the mounting surface s anchor blocks by inserting the screws included in the package through the screw holes around the edge of the FMB mount When placing the dome cover look for the carved triangle mark on both dome cover a...

Page 4: ...e device 2 Start the Microsoft Internet Explorer web browser and enter the IP address of the device 3 Web streaming and device configurations are supported through ActiveX program When the ActiveX installation pop up window appears authorize and install the ActiveX setup exe Custom IP Environment IPAdminTool is a management tool which automatically scans all of the network products for users to pe...

Page 5: ...tiveX control Once the device s proper IP address has been identified type the URL in a web browser to access the camera At first time access installation window may pop up 1 When the browser asks to install the AxUMF software click Install to proceed 2 When Setup installation pop up window appears click Install to proceed with rest of installations Note i Depending on system OS and Internet Explo...

Page 6: ...r devices refer to the manuals as RIVA Web Interface Manual Full HD Series or VCAsys User Manual Online Help which is available on www rivatech de homepage 5 Reboot Perform the following procedures to reset your device 1 Press the reset button for 2 seconds while the device is in use 2 Wait for the system to reboot Caution Please do not hold the reset button for more than 2 seconds Otherwise the c...

Page 7: ... source unplugged or damage occurred on firmware file during the system boot The messages like below will appear on the webpage when your device has been rebooted in safe mode Then you should follow the instructions on the webpage according to the steps in a row Note i There is another method to update firmware which is using IPAdminTool Please refer to IPAdminTool User s Manual pdf for the detail...

Page 8: ...1 58 88 7D 125 A2 162 C7 199 EC 236 0F 15 34 52 59 89 7E 126 A3 163 C8 200 ED 237 10 16 35 53 5A 90 7F 127 A4 164 C9 201 EE 238 11 17 36 54 5B 91 80 128 A5 165 CA 202 EF 239 12 18 37 55 5C 92 81 129 A6 166 CB 203 F0 240 13 19 38 56 5D 93 82 130 A7 167 CC 204 F1 241 14 20 39 57 5E 94 83 131 A8 168 CD 205 F2 242 15 21 3A 58 5F 95 84 132 A9 169 CE 206 F3 243 16 22 3B 59 60 96 85 133 AA 170 CF 207 F4 ...