background image

28

 

 
 
 
 

 

 

 
 

www.rivatech.de 

APPENDIX (D): HEXADECIMAL-
DECIMAL CONVERSION TABLE 

Refer to the following table when converting the MAC address of the device to the IP address. 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

Hex  Dec 

 

25 

37 

 

4A 

74 

 

6F  111 

 

94  148 

 

B9  185 

 

DE  222 

 

26 

38 

 

4B 

75 

 

70  112 

 

95  149 

 

BA  186 

 

DF  223 

 

27 

39 

 

4C 

76 

 

71  113 

 

96  150 

 

BB  187 

 

E0  224 

 

28 

40 

 

4D 

77 

 

72  114 

 

97  151 

 

BC  188 

 

E1  225 

 

29 

41 

 

4E 

78 

 

73  115 

 

98  152 

 

BD  189 

 

E2  226 

 

2A 

42 

 

4F 

79 

 

74  116 

 

99  153 

 

BE  190 

 

E3  227 

 

2B 

43 

 

50 

80 

 

75  117 

 

9A  154 

 

BF  191 

 

E4  228 

 

2C 

44 

 

51 

81 

 

76  118 

 

9B  155 

 

C0  192 

 

E5  229 

 

2D 

45 

 

52 

82 

 

77  119 

 

9C  156 

 

C1  193 

 

E6  230 

 

2E 

46 

 

53 

83 

 

78  120 

 

9D  157 

 

C2  194 

 

E7  231 

0A 

10 

 

2F 

47 

 

54 

84 

 

79  121 

 

9E  158 

 

C3  195 

 

E8  232 

0B 

11 

 

30 

48 

 

55 

85 

 

7A  122 

 

9F  159 

 

C4  196 

 

E9  233 

0C 

12 

 

31 

49 

 

56 

86 

 

7B  123 

 

A0  160 

 

C5  197 

 

EA  234 

0D 

13 

 

32 

50 

 

57 

87 

 

7C  124 

 

A1  161 

 

C6  198 

 

EB  235 

0E 

14 

 

33 

51 

 

58 

88 

 

7D  125 

 

A2  162 

 

C7  199 

 

EC  236 

0F 

15 

 

34 

52 

 

59 

89 

 

7E  126 

 

A3  163 

 

C8  200 

 

ED  237 

10 

16 

 

35 

53 

 

5A 

90 

 

7F  127 

 

A4  164 

 

C9  201 

 

EE 

238 

11 

17 

 

36 

54 

 

5B 

91 

 

80  128 

 

A5  165 

 

CA  202 

 

EF 

239 

12 

18 

 

37 

55 

 

5C 

92 

 

81  129 

 

A6  166 

 

CB  203 

 

F0  240 

13 

19 

 

38 

56 

 

5D 

93 

 

82  130 

 

A7  167 

 

CC  204 

 

F1  241 

14 

20 

 

39 

57 

 

5E 

94 

 

83  131 

 

A8  168 

 

CD  205 

 

F2  242 

15 

21 

 

3A 

58 

 

5F 

95 

 

84  132 

 

A9  169 

 

CE  206 

 

F3  243 

16 

22 

 

3B 

59 

 

60 

96 

 

85  133 

 

AA  170 

 

CF  207 

 

F4  244 

17 

23 

 

3C 

60 

 

61 

97 

 

86  134 

 

AB  171 

 

D0  208 

 

F5  245 

18 

24 

 

3D 

61 

 

62 

98 

 

87  135 

 

AC  172 

 

D1  209 

 

F6  246 

19 

25 

 

3E 

62 

 

63 

99 

 

88  136 

 

AD  173 

 

D2  210 

 

F7  247 

1A 

26 

 

3F 

63 

 

64  100 

 

89  137 

 

AE  174 

 

D3  211 

 

F8  248 

1B 

27 

 

40 

64 

 

65  101 

 

8A  138 

 

AF  175 

 

D4  212 

 

F9  249 

1C 

28 

 

41 

65 

 

66  102 

 

8B  139 

 

B0  176 

 

D5  213 

 

FA  250 

1D 

29 

 

42 

66 

 

67  103 

 

8C  140 

 

B1  177 

 

D6  214 

 

FB  251 

1E 

30 

 

43 

67 

 

68  104 

 

8D  141 

 

B2  178 

 

D7  215 

 

FC  252 

1F 

31 

 

44 

68 

 

69  105 

 

8E  142 

 

B3  179 

 

D8  216 

 

FD  253 

20 

32 

 

45 

69 

 

6A  106 

 

8F  143 

 

B4  180 

 

D9  217 

 

FE 

254 

21 

33 

 

46 

70 

 

6B  107 

 

90  144 

 

B5  181 

 

DA  218 

 

FF 

255 

22 

34 

 

47 

71 

 

6C  108 

 

91  145 

 

B6  182 

 

DB  219 

 

 

 

23 

35 

 

48 

72 

 

6D  109 

 

92  146 

 

B7  183 

 

DC  220 

 

 

 

24 

36 

 

49 

73 

 

6E  110 

 

93  147 

 

B8  184 

 

DD  221 

 

 

 

Summary of Contents for RC1202HD

Page 1: ...1 Fehler Unbekannter Name für Dokument Eigenschaft www rivatech de RC1202HD Installation Guide ...

Page 2: ...ERVICE PERSONNEL FOR INTERNAL PART SERVICES This symbol is intended to alert the user the presence of un insulated dangerous voltage within the product s enclosure which may be sufficient magnitude to constitute a electric shock risk to persons This symbol is intended to alert the user the presence of important operating and maintenance servicing instructions within the guide manual ...

Page 3: ...15 5 CONFIGURATION 16 5 1 Set up network environment 16 5 1 1 Generic IP Environment 16 5 1 2 Custom IP Environment 17 5 2 View video on web page 19 5 2 1 View video using IPAdmin Tool 21 5 3 Reset 22 5 4 Factory Default 22 APPENDIX A SPECIFICATIONS 24 Summary 24 Electrical Characteristics 25 Environment Condition 25 Mechanical Condition 25 APPENDIX B POWER OVER ETHERNET 26 APPENDIX C DIMENSIONS 2...

Page 4: ...p Audio compression G 711 µLaw aLaw PCM Analog video out for installation only Video motion detection supported Two way mono audio supported Network RTSP HTTP protocol support 10 100 Base T Ethernet Additional Features RS 485 support MicroSD card slot support Local storage PoE support Built in Video Content Analysis Burnt in text support SDK Software Development Kit support When VCA is activated f...

Page 5: ...nting adaptor clamping core and quick installation guide Unpack carefully and handle the equipment with care Camera DC power adaptor Lens Terminal block Power adaptor jack Screws Adaptor for mounting the camera Quick installation guide Clamping core To prevent electromagnetic interference The above contents are subject to change without prior notice Note i ...

Page 6: ...6 www rivatech de 3 PART NAMES 3 1 Rear View 3 2 Side View ...

Page 7: ... analog video signal is only 3 minutes present and go back automatically to none video output mode only installation process 3 11 pin terminal block for D I D O audio and serial communication Refer to the section 4 3 Connecting Cables for more specific information 4 Analog Video Out Connector Use BNC cable not supplied to connect between the camera and monitor to verify image focuses at the instal...

Page 8: ...tion register The default is off 7 Network Port Use the RJ45 LAN connector for connecting the camera to network or supplying PoE power 8 USB 2 0 Port Plug an USB flash drive or wireless LAN device 9 SD Card Slot Support memory cards up to 32GB 10 Auto Iris Lens Connector The 4 pin connector for an DDC drive auto iris lens 11 Light Sensor The light sensor is used to detect the level of ambient ligh...

Page 9: ...ex diurnal temperature variations higher than 10 C condensation or thermal expansion are likely to occur in camera and lens parts causing lens focus to shift time to time Be advised to consider the environment condition impact when installing the device in a long term To mount a DC auto iris lens 1 Place the lens mount to the camera and tighten the mount by turning clockwise 2 Connect the lens cab...

Page 10: ...nting Adaptor The provided mounting adaptor is designed for installing an IP camera device on a bracket or tripod Tripod screw holes are available on both top and bottom of the camera Refer to the following image for instruction Mounting screws that are longer than 7mm may damage the camera s inside parts Note i 2 1 4 3 PIN DC Auto Iris Lens 1 Damp 2 Damp 3 Drive _ 4 Drive 4 pin connector ...

Page 11: ...he LAN cable is connected the orange LED light will become solid and green LED will blink every 250 millisecond Power Connection The camera can be powered from either 12VDC or PoE If the camera is powered via PoE refer to Appendix B Power over Ethernet for more details To operate your camera using 12VDC make sure the polarity is correct before connecting the power cable Incorrect connection may ca...

Page 12: ...iewing through the analog video connection The video output configuration must be set before you connect the power cable When changes get made while power cable is connected users must restart the device to reflect the change Once the PAL NTSC button is pressed the video display lasts for 3 minutes before it goes back to no video output mode Users cannot adjust the video brightness while connected...

Page 13: ...amera s configuration webpage Input voltage range 0VDC minimum to 5VDC maximum Max 50mA Input voltage threshold 1 5V Do not exceed the maximum input voltage or relay rate Alarm DO connection Caution 5V DI COM DI COM Relay Type Voltage Type Output of Sensor Output of Sensor Internal Internal Mic Amp Speaker ETHERNET MICRO SD DC12V DO DI 1 Out Out 1 VIDEO C C In AUDIO SW1 SW2 SW3 SW5 SW6 N A N A N A...

Page 14: ...elay Rating Max 24VDC 50mA Do not exceed the maximum relay rating RS 485 Connection The RS 485 serial port consists of TRX RX and TRX RX as following Caution TRX RX RS 485 Application TRX RX TX TX PTZ Device RS 485 Device DO COM Relay Type Device Internal ...

Page 15: ... can configure image settings The menu of image attribute are available under Video Appearance menu in Setup Video Audio Camera The following features can be adjusted Brightness Contrast Saturation Orientation For more detailed information refer to the provided RIVA Web Interface Manual ...

Page 16: ...IP Environment In case of generic private network environment where IP address 192 168 XXX XXX are used users may view the live streaming images on a web page using the device s default IP address 1 Convert the device s MAC address to the IP address Refer to the Hexadecimal Decimal Conversion Chart at the end of the manual The MAC address of the device is attached on the side or bottom of the devi...

Page 17: ...oad from www rivatech de homepage IPAdminTool is a management tool which automatically scans all of the network products for users to perform administrative tasks which includes network configurations firmware update device reboot and device organizations To modify the device s default IP address for customized network area 1 Find the device from the IPAdminTool s list and highlight the device s n...

Page 18: ...ept the last 2 sets of IP Address which are to be the unique numbers for the device Refer to the image above for the setting 4 Click Setup to complete the modification When the dialog box appears to request user name and password enter the default value for the administrator account case sensitive as below ID root Password pass PC environment Info Give new unique IP address in last two sets and mi...

Page 19: ...live streaming images through a web browser The default username and password is root pass 1 The browser asks to install the ActiveX Click Allow 2 Setup exe installation link or pop up window appears depends on Microsoft Internet Explorer version Proceed with rest of setup installation ...

Page 20: ...e start the web browser again and check if video stream is displayed in the main view frame If This software requires the Microsoft XML Parser V6 or higher Please download MSXML6 from the Microsoft website to continue Error code Cannot create XMLDOMDocument message appears download and install the Microsoft Core XML Services MSXML 6 0 ...

Page 21: ... product list select the device by highlighting it 2 Right click the mouse and select Web view 3 The system s default web browser opens the device s address Please take care that the default system web browser is Microsoft Internet Explorer to support ActiveX plug in Whether directly accessing the streaming video through typing IP address on a web page or taking steps through IPAdminTool the Activ...

Page 22: ...about 5 seconds when green LED blinks at rate of 200ms 3 Wait for the system to reboot Alternative you can reset the device to the factory default settings via webpage menu 1 Access the device s webpage 2 From Setup page go to Maintenance Reset All Settings 3 Press the Reset All Settings button Click OK when popup message Do you want to reset all settings appears 4 After few seconds of loading ano...

Page 23: ...tion To learn more about using other features of your devices refer to the manuals as Web Interface Manual or VCAsys_Online_Help which is available on USB stick or on www rivatech de homepage IP address 192 168 xx yy Network mask 255 255 0 0 Gateway 192 168 0 1 User ID root Password pass ...

Page 24: ...1080 1280x720 800x450 480x270 320x180 Compression FPS Configurable up to 30fps 1080p Motion Detection Built in Burnt in Text Digital Video stream overlay text Output Analog video output for installation only Audio Input Output 1 1 channel Compression Format G 711 Function Digital Input 1 channel Digital Output 1 channel RS 485 Support Network 10 100 Base T Protocol TCP IP UDP IP HTTP RTSP RTCP RTP...

Page 25: ...49 Vp p 39 KΩ Audio Output Lineout 46mW Power 16 Ω D I Max 50mA 5VDC 1 5V threshold D O Max 50mA 24VDC On state resistance 50 Ω max continuous Environment Condition Operating Temperature DC12V 0 C 50 C 32 F 122 F PoE 0 C 50 C 32 F 122 F Operating Humidity Up to 85 RH Mechanical Condition Material Aluminum Die Casting Color White Dimension 71 W x 64 H x 140 D mm Weight Approx 500g ...

Page 26: ...er consumption is 5 28 W or 5 40W when the fan is on Note For proper activation of 12V PoE the Category 5 cable must be shorter than 140m and conform the PoE standard PoE compatibility With non Power Sourcing Equipment PSE When it is connected with non PSE the power adaptor should be used With power adaptor Connecting both PSE and power adaptor do not cause any harms to the products Disconnecting ...

Page 27: ...27 www rivatech de APPENDIX C DIMENSIONS UNIT mm ...

Page 28: ...14 33 51 58 88 7D 125 A2 162 C7 199 EC 236 0F 15 34 52 59 89 7E 126 A3 163 C8 200 ED 237 10 16 35 53 5A 90 7F 127 A4 164 C9 201 EE 238 11 17 36 54 5B 91 80 128 A5 165 CA 202 EF 239 12 18 37 55 5C 92 81 129 A6 166 CB 203 F0 240 13 19 38 56 5D 93 82 130 A7 167 CC 204 F1 241 14 20 39 57 5E 94 83 131 A8 168 CD 205 F2 242 15 21 3A 58 5F 95 84 132 A9 169 CE 206 F3 243 16 22 3B 59 60 96 85 133 AA 170 CF ...

Page 29: ...ents 01A 01 03 30 2012 Created 01A 02 04 24 2012 Overall modification and device function verification 01A 03 05 03 2012 Configuration update 01A 04 06 25 2012 DI DO specification correction 01A 05 07 03 2012 Supporting protocol revised removed SOCK and SSH ...

Reviews: