where is out of the touch of people

 
DMX-512 control connection: 

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the 

other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving 

head together through serial linking. The cable needed should be two core, screened cable 

with XLR input and output connectors. Please refer to the diagram below. 

 

 
DMX-512 connection with DMX terminator: 

For installations where the DMX cable has to run a long distance or is in an electrically noisy 

environment, such as in a discotheque, it is recommended to  use a DMX terminator. This 

helps  in  preventing  corruption  of  the  digital  control  signal  by  electrical  noise.  The  DMX 

terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3,which 

is  then  plugged  into  the  output  XLR  socket  of  the  last  fixture  in  the  chain.  Please  see 

illustrations below. 

 

TECHNICAL SPECIFICATIN 

DMX channel

12/17ch mode   

Control mode

DMX512

master-slave, auto, sound 

LCD display screen 

Voltage

AC100V-240V

50/60Hz 

Summary of Contents for ML-WZ007

Page 1: ...7x40W ZOOM ML WZ007 LED MOVING HEAD User Manual KEEP THIS MANUAL FOR FUTURE NEED ...

Page 2: ...NIT 8 HOW TO CONTROL THE UNIT 10 CLEANING AND MAINTENANCE 15 STATEMENT The product has well capability and intact packing when leave factory All of the user should comply with warning item and manual any misuse cause of the damages are not included in our guarantee and also cannot be responsible for any malfunction problem owing to ignore the manual ...

Page 3: ...her with the product Name Quantity Unit Remark DMX CABLE 1 PCS POWER CABLE 1 PCS SAFETY INSTRUCTION Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet ...

Page 4: ...cked DO NOT attempt installation and or operation without knowledge how to do so DO NOT permit operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come DO NOT shake fixture avoid brute force when installing and or operati...

Page 5: ... installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating And make sure that the structure to which you are attaching the ...

Page 6: ...ith DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged into t...

Page 7: ...ving head wash zoom Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice CONTROL SYSTEM The DMX512 is widely used in intelligent lighting control with a DMX 512 controller Connect several lights together dmx in and dmx out 3 pin XLR connectors Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal ...

Page 8: ...the DOWN and UP buttons to change the mode Once the required mode has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu The main functions are as below DmxAddr 001 512 Fix Set Ch Mode STD HIS Run Mode DMX Host Pan Inv Close Open ...

Page 9: ...o Cur Time xxxh Show Time xxxh PowerCnt xxx SenSor Pan OK NG Tilt OK NG Zoom OK NG Temp OK NG Fan OK NG TempInfo Temprat xxx C FanSpeed xxxx RPM Soft Ver Panel Vx xxx Motor Vx xxx Home Set Password 0 255 Pan 0 255 Tilt 0 255 Zoom 0 255 Red 0 255 Green 0 255 Blue 0 255 White 0 255 ...

Page 10: ...hen ENTER press Mode Esc back to main menu 2 Fix setting 2 1 channel setting 2 optional channel modes 12 ch and 17 ch to DMX512 signal 2 2 running mode Run running mode select Master mode and Slave mode and sound control 2 3 Pan Inv Reverse PAN Pan info forward and reverse settings select OFF forward select ON reverse 2 4 Tilt Inv Reverse Tilt Tilt info forward and reverse settings select OFF forw...

Page 11: ... deault OFF stay cur setting press ENTER confirm 7 display setting language Chinese English display flip display mode setting CHANNEL DESCRIPTION 17 CHANNEL CH FUNCTION VALUE DESCRIPTION 1 Pan 0 255 Pan Rotation 2 Pan Fine 0 255 Pan Fine 3 Tilt 0 255 Tilt Rotation 4 Tilt Fine 0 255 Tilt Fine 5 P T Speed 0 255 P T Speed 6 Red 0 255 LED OFF LED ON 7 Green 0 255 LED OFF LED ON 8 Blue 0 255 LED OFF LE...

Page 12: ...SED 12 CCT 225 255 2500 K 189 224 3200 K 145 188 4000 K 118 144 5000 K 100 117 5600 K 55 99 6000 K 11 54 7000 K 10 8000 K 0 9 UNUSED RANGE 13 Macro colour 209 255 White 208 Dirty White 207 Alice Blue 191 206 Congo Blue 184 190 Dark Steel Blue 180 183 Deep lavender 179 Lilac Tint 175 178 Daylight Blue 174 Flame Red 172 173 Bastard Amber 168 171 Deep Orange 162 167 Pale Gold 157 161 Apricot 151 156 ...

Page 13: ...130 Dark Blue 128 Light Blue 127 Steel Blue 126 Med Blu Green 125 Peacock Blue 123 124 Magenta 121 122 Dark Pink 120 Middle Rose 119 Light Salmon 118 English Rose 117 Light Rose 115 116 Orange 114 Deep Amber 113 Straw 112 Light Amber 110 111 Spring Yellow 100 109 Dark yellow green 89 99 Just Blue 78 88 Sky Blue 68 77 Lavender 62 67 Light Lavender 49 61 Pink Carnation 46 48 Medium Pink ...

Page 14: ...ite 5000 K 17 White 3700 K 16 White 7000 K 15 Magenta 14 Yellow 13 Cyan 12 Blue 11 Green 10 Red 0 9 Macro color OFF 14 Zoom 0 255 NARROW BEAM WIDE BEAM 15 Reset 0 127 UNUSED RANGE 128 255 COMPLETE RESET 16 Control 0 255 Control 17 Effect 0 CLOSED 1 100 Wave 101 200 Dream 201 255 CLOSED CHANNEL DESCRIPTION 12 CHANNEL CH FUNCTION VALUE DESCRIPTION 1 Pan 0 255 Pan ...

Page 15: ...8 255 COMPLETE RESET CLEANING AND MAINTENANCE CLEANING Frequent cleaning is recommended to insure proper function optimized light output and an extended life The frequency of cleaning depends on the environment in which the fixture operates damp smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture s optics Clean the external lens surface at least every 20 ...

Page 16: ...rcuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for d...

Page 17: ...17 Factroy No 31 Zhongxing Road Baiyun District Guangzhou China 86 20 2904 6476 info ricostagelight com www riukoe com Facebook YouTube ...

Reviews: