S
WITCH
O
UTPUT
O
PTIONS
–A
LLOWS
C
ONTROL OF AN
E
XTERNAL
D
EVICE
.....
(e.g., a gate controller, a strobe light, or any relay controlled device.)
The switch output is a simple 1-Amp relay contact closure that
can be used to
OPEN
and
CLOSE
a gate, switch on a light,
sound an alarm or any other application where remote control
of an ON/OFF switch is required. The OUTPOST
®
Callbox
can be programmed to
OPEN
and
CLOSE
the Switch Output
when one of the following programmed conditions is met.
The Callbox can be programmed to alternately
OPEN
and
CLOSE
the switch using a single 2-tone code, or can be PC
programmed for separate
OPEN
and
CLOSE
2-tone codes.
Field programming offers nine 2-tone codes that correspond
to field programmable 2-tone codes available in select
RITRON portable and base radios.
N o S w i t c h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ( PC or FP)
Select this option for no switch operation.
S w i t c h O n W h e n C a l l e d . . . . . . . . . . . . . . . . . . . . . . ( PC or FP)
With this option selected the switch will
CLOSE
when the
Callbox first receives a call. The switch will remain
CLOSED
until the
ON/PTT
button is pressed or the RQX Reset Time
expires. This option is not applicable if the Callbox is
programmed for Automatic Turn-Off.
S w i t c h O n W h e n C a l l b o x i n U s e . . . . . . . . . . ( PC or FP)
This option will
CLOSE
the switch when the Callbox first
sends or receives a call. The switch will remain closed until
the RQX Reset Time expires, which also turns the radio off if it
is programmed for Automatic Turn-Off.
Switch On When Active with Turn-Off Code . . . . . . . . . . . ( PC)
This option operates the same as Switch On When Callbox in
Use with the added ability to
OPEN
the switch when a unique
2-Tone Turn-Off Code is received. Unlike the Switch On
When Callbox in Use feature, the switch will not
OPEN
when
the RQX Reset Time expires unless the Callbox is
programmed for Automatic Turn-Off. See “2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTINGS
” on page
21
for details on programming a
2-Tone Turn-Off code.
G a t e G u a r d
®
– M o m e n t a r y f o r 1 s e c .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ( PC or FP)
With this option selected the switch will momentarily
CLOSE
when a unique 2-Tone code is received. The switch will
remain
CLOSED
for the programmed period of time,
programmable for 1-255 seconds. See “2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTINGS
” on page
21
for details on programming a
2-Tone Decode Code. Single-Digit field programming the
Callbox for GateGuard
®
operation places the radio into this
momentary mode.
G a t e G u a r d
®
– T o g g l e . . . . . . . . . . . . . . . . . . . . . . . . . ( PC or FP)
With this option selected the switch will alternately
OPEN
and
CLOSE
when it receives a unique 2-Tone code. After the 2-
tone code is received the Callbox will transmit a
SINGLE
BEEP
if the switch has been
OPENED
and a
DOUBLE BEEP
if the switch has been
CLOSED
. The switch will open when
the Callbox turns off if it is programmed for Automatic Turn-
Off. See “2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTINGS
” on page
21
for
details on programming a 2-Tone Decode Code.
G a t e G u a r d
®
– O n C o d e / O f f C o d e . . . . . . . . . . . . . . ( PC)
When this option is selected the switch will
CLOSE
when a
unique 2-Tone code is received, and
OPEN
when the 2-Tone
Turn-Off code is received. The switch will
OPEN
when the
Callbox turns off if it is programmed for Automatic Turn-Off.
See “2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTINGS
” on page
21
for
details on programming a 2-Tone Decode Code and a 2-Tone
Turn-Off Code.
20