6 Series OUTPOST
®
Wireless Callbox
Programmable Features
Have questions? Call 800-USA-1-USA (800-872-1872) or visit our website at www.ritron.com
19
S
WITCH
O
UTPUT
O
PTIONS
–A
LLOWS
C
ONTROL OF AN
E
XTERNAL
D
EVICE
...................................................................................
(e.g., a gate controller, a strobe light, or any relay controlled device.)
The switch output is a simple 1-Amp relay contact
closure that can be used to OPEN and CLOSE a gate,
switch on a light, sound an alarm or any other application
where remote control of an ON/OFF switch is required.
The OUTPOST
®
Callbox can be programmed to OPEN
and CLOSE the Switch Output when one of the following
programmed conditions is met.
The Callbox can be programmed to alternately OPEN
and CLOSE the switch using a single 2-tone code, or
can be PC programmed for separate OPEN and CLOSE
2-tone codes. Field programming offers nine 2-tone
codes that correspond to field programmable 2-tone
codes available in select RITRON portable and base
radios.
N o S w i t c h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ( PC or FP)
Select this option for no switch operation.
S w i t c h O n W h e n C a l l e d . . . . . . . . . . . . . . . . . ( PC or FP)
With this option selected the switch will CLOSE when the
Callbox first receives a call. The switch will remain
CLOSED until the ON/PTT button is pressed or the RQX
Reset Time expires. This option is not applicable if the
Callbox is programmed for Automatic Turn-Off.
S w i t c h O n W h e n C a l l b o x i n U s e . . . . . ( PC or FP)
This option will CLOSE the switch when the Callbox first
sends or receives a call. The switch will remain closed
until the RQX Reset Time expires, which also turns the
radio off if it is programmed for Automatic Turn-Off.
Switch On When Active with Turn-Off Code . . . . . . ( PC)
This option operates the same as Switch On When
Callbox in Use with the added ability to OPEN the switch
when a unique 2-Tone Turn-Off Code is received. Unlike
the Switch On When Callbox in Use feature, the switch
will not OPEN when the RQX Reset Time expires unless
the Callbox is programmed for Automatic Turn-Off. See
“
2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTING
” on page 20 for
details on programming a 2-Tone Turn-Off code.
G a t e G u a r d
®
– M o m e n t a r y f o r 1 s e c .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ( PC or FP)
With this option selected the switch will momentarily
CLOSE when a unique 2-Tone code is received. The
switch will remain CLOSED for the programmed period
of time, programmable for 1-255 seconds. See “
2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTING
” on page 20 for details on
programming a 2-Tone Decode Code. Field
programming the Callbox for GateGuard
®
operation
places the radio into this momentary mode.
G a t e G u a r d
®
– T o g g l e . . . . . . . . . . . . . . . . . . . . ( PC or FP)
With this option selected the switch will alternately OPEN
and CLOSE when it receives a unique 2-Tone code.
After the 2-tone code is received the Callbox will transmit
a SINGLE BEEP if the switch has been OPENED and a
DOUBLE BEEP if the switch has been CLOSED. The
switch will open when the Callbox turns off if it is
programmed for Automatic Turn-Off. See “
2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTING
” on page 20 for details on
programming a 2-Tone Decode Code.
G a t e G u a r d
®
– O n C o d e / O f f C o d e . . . . . . . . . ( PC)
When this option is selected the switch will CLOSE when
a unique 2-Tone code is received, and OPEN when the
2-Tone Turn-Off code is received. The switch will OPEN
when the Callbox turns off if it is programmed for
Automatic Turn-Off. See “
2-T
ONE
D
ECODE
(R
ECEIVE
)
S
ETTING
” on page 20 for details on programming a 2-
Tone Decode Code and a 2-Tone Turn-Off Code.