![ritetemp 8050C Install Manual Download Page 8](http://html.mh-extra.com/html/ritetemp/8050c/8050c_install-manual_1464648008.webp)
PG
14
PG
13
R
G
Y
W
C
RH
or
From Furna
ce
and AC unit
STEP 1 -
Connect the
Y
wire
to the
Y
terminal on the
thermostat. This connects to
the Cooler compressor.
STEP 2 -
Connect the
RH
or
R
wire to the
RH
terminal on the thermostat.
This connects the Heater/Cooler Power.
STEP 3 -
Connect the
W
wire to the
W
terminal
on the thermostat.
This connects to the heater control line.
STEP 4 -
Connect the
G
wire to the
G
terminal on the Thermostat.
This connects to the Fan.
Your HVAC system is now connected to the thermostat.
Go To Page 10
4 WIRE
NON-HEAT PUMP
NOTE: Wires marked with
the dotted line are optional.
HVAC SYSTEM
jumper
wire
Heat
Power
Heat
W
G
RH
C
FAN
Y
Cool
Comp
Thermostat
From Furna
ce
and AC unit
G
W
Y
RH
RC
C
STEP 1 -
Remove the Jumper wire.
STEP 2 -
Connect the
Y
wire
to the
Y
terminal on the
thermostat. This connects to
the Cooler compressor.
STEP 3 -
Connect the
RH
wire to the
RH
terminal
on the thermostat. This connects to the Heater
Power.
STEP 4 -
Connect the
RC
wire to the
RC
terminal
on the thermostat. This connects to the Cooling
Power.
STEP 5 -
Connect the
W
wire to the
W
terminal on the thermostat.
This connects to the heater control line.
STEP 6 -
Connect the
G
wire to the
G
terminal on the Thermostat.
This connects to the Fan.
Your HVAC system is now connected to the thermostat.
Go To Page 10
5 WIRE
NON-HEAT PUMP
NOTE: Wires marked with
the dotted line are optional.
HVAC SYSTEM
Remove
jumper
wire
HEAT
Power
Heat
W
G
RH
RC
C
FAN
Y
Cool
Comp
COOL
Power
Thermostat