A.

Location  - 

Installing  the  fountain  in  a  location  that  offers  protection  from  the  wind  will  enhance  the

performance  of  the  fountain.  Livestock  will  tend  to  gather  in  this  protected  area,  enticing  them  to  drink  more. 

Access panel should be opposite of prevailing winter wind to give additional protection to the supply line.

  

B.

Water  Supply  Line

  -  Horizontal  underground  water  line  should  be  sized  to  account  for  pressure  drop,

relating  to  distance,  and  placed  one  foot  below  frost  line.  A  one-inch  vertical  supply  pipe  is  recommended.  A 

shut-off valve should be installed under fountain to allow for easier servicing. For optimum serviceability, a stop 

and waste valve can be installed below frost level to drain water when unit is not in use. Vertical supply line must 

be centered in riser tube to provide an air space between the line and frozen ground outside of tube. Flush water 

supply line thoroughly before connection to fountain. Water supplies with foreign material such as sand, rust, etc. 

may require a filter to keep fountain valve working properly. 

C.

Electric Supply 

– It is generally most cost effective to run your electrical supply line at the same time you are

trenching for your water supply. 

WARNING:  ANY  ELECTRICAL  SERVICE  MUST  BE  INSTALLED  AND 

MAINTAINED BY A QUALIFIED ELECTRICIAN.

 

D.

Riser Tube

 - Install a riser tube and extend it at least one foot below frost line

or down to horizontal underground water line. For optimum water line 

protection, use 

the 12” diameter insulated Ritchie 

Thermal Tube, part numbers and sizes are shown 

to the right. Tube opening must be kept clear.  

NOTE: 

The supply line touching the riser tube is the most common cause of the supply line freezing. 

Do not surround the supply line with insulation, wood, or other foreign material. Any foreign material in 

the tube may cause frost to migrate to the supply line causing it to freeze.

 

Ritchie Thermal Tube 

Part # 

Description 

18158 

1’ Top Section 

16417 

2’ Top Section 

16612 

4’ Top Section 

16416 

2’ Extension 

SHUTOFF VALVE

WATER SUPPLY

ELECTRICAL SERVICE
PER LOCAL CODE

ANCHOR BOLT

STANDARD DRAIN

UNDERGROUND DRAIN
OPTIONAL

CONCRETE

RISER TUBE

FROST LINE

CattleMaster Series Instruction Manual

1

January 1, 2020

Summary of Contents for CattleMaster CM10T

Page 1: ...watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructions before...

Page 2: ...uch as sand rust etc may require a filter to keep fountain valve working properly C Electric Supply It is generally most cost effective to run your electrical supply line at the same time you are tren...

Page 3: ...s before location can be verified with unit H Hose Connection Remove side panels and cover Remove valve assembly from standpipe Connect the hose to the valve assembly barb fitting and use a hose clamp...

Page 4: ...er to the fountain For wiring connections see wiring diagram WARNING DISCONNECT POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN EXTENDED AMOUNT OF TIME FAILURE TO TURN OFF POWER CAN RESULT IN DAMAG...

Page 5: ...WIRING DIAGRAM 120V SINGLE PHASE WIRING DIAGRAM 240V SINGLE PHASE CattleMaster Series Instruction Manual 4 January 1 2020...

Page 6: ...insulation around heater P Install Side Access Panel Once all water line connections have been checked for leaks and electrical hook up is complete the side access door may be installed Q Children sh...

Page 7: ...w 5 40 psi 34 275 kPa Red 11101 20 Moderate 40 60 psi 275 414 kPa Green 15377 16 5 High 60 80 psi 414 552 kPa NOTE Maximum inlet water pressure for each valve is shown above If water pressure is extre...

Page 8: ...lug to the bracket and reattach on the opposite side of the bracket Be sure to include the green wire under the screw 7 Relocate the 3 Ritchie plug Item 6 to the other end of the casing Loosen wing nu...

Page 9: ...kg 21 17678 Drain Elbow Fitting 1 18320 O Ring Fenwal 6 pkg 1 pkg 22 18849 Ritchie 2 Plug pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg 23 18852 CM Drain Assembly pkg 1 pkg 8 18266 Frame Bolt Wshr SS 3...

Page 10: ...g 21 17678 Drain Elbow Fitting 1 18320 O Ring Fenwal 6 pkg 1 pkg 22 18849 Ritchie 2 Plug pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg 23 18852 CM Drain Assembly pkg 1 pkg 8 18266 Frame Bolt Wshr SS 3...

Page 11: ...kg 21 17678 Drain Elbow Fitting 1 18320 O Ring Fenwal 6 pkg 1 pkg 22 18849 Ritchie 2 Plug pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg 23 18852 CM Drain Assembly pkg 1 pkg 8 18266 Frame Bolt Wshr SS 3...

Page 12: ...kg 21 17678 Drain Elbow Fitting 1 18320 O Ring Fenwal 6 pkg 1 pkg 22 18849 Ritchie 2 Plug pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg 23 18852 CM Drain Assembly pkg 1 pkg 8 18266 Frame Bolt Wshr SS 3...

Page 13: ...ered in riser tube Check that riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between...

Page 14: ...ights which vary from state to state All warranty claims must be processed through an Authorized Ritchie Dealer Distributor Proof of purchase is required This warranty is not transferable The period o...

Reviews: