15
Aux1
Setting of function modes AUX. 1 output:
0: Contact for the connection of a light indicator bollard (see link diagram AUX).
Light indicator ON = bollard down
Flashing light 1 flash/sec = bollard is performing a lowering maneuver
Flashing light 2 flash/sec= bollard is performing a raising maneuver
Light indicator OFF = Bollard UP
1: AUX 1 contact CLOSED only with raised bollard; OPEN with bollard down or during the
maneuver .
2: Contact for the connection of a siren /allarm , CLOSED during the raising maneuver , see
link diagram drawing 6
3: Output repeat the input status LS1
4: Output reverse the status of input LS1
0-4-(0)
Aux2
Setting of function modes AUX 2 output.
0: Contact for the connection of a light indicator bollard (see link diagram AUX).
Light indicator ON = bollard down
Flashing light 1 flash/sec = bollard is performing a lowering maneuver
Flashing light 2 flash/sec= bollard is performing a raising maneuver
Light indicator OFF = Bollard UP
1: AUX 2 contact CLOSED only with raised bollard; OPEN with bollard down or during the
maneuver .
2: Contact for the connection of a siren /allarm , CLOSED during the raising maneuver , see
link diagram drawing 6
3: Output repeat the input status LS2
4: Output reverse the status of input LS2
0-4-(0)
LOGIC (
LOG
)
MENU
FUNCTION
ON-OFF-(Default)
MEMO
IbL
Enable or disable the condominium function.
On: Enable Condominium function. Step by Step impulse of the transmitter is inhibited
during the lowering maneuver.
OFF: Disable condominium function
(OFF)
IbCA
Enable or disable the step by step comands of the transmitter during TCA automatic raising
delay time.
On: Disable step by step commands
Off: Enable step by step commands
(OFF)
SCL
Enable or disable the fast raising maneuver.
On: Enable fast raising maneuver. With bollard down or during the lowering maneuver, the
intervention of the photocell causes the automatic raising of the bollard after 3 sec. Con
dissuasore abbassato o in fase di discesa l’intervento della fotocellula provoca la risalita
automatica dopo 3 s.
Enable only with TC>0
Off: Disable fast raising maneuver.
(OFF)
PP
Set the functioning mode of the transmitter
On: mode : DOWN > UP > DOWN >
Off: mode: DOWN > STOP > UP > STOP >
(ON)
PRE
Enable or disable the pre-flashing function
On: Enable pre-flashing. Flashing light output (7/8 e 12/13) is activated 3s before the raising
maneuver starts.
Off: Disable pre-flashing function.
(OFF)
htr
Enable or Disable the dead man function
On: death man functioning.
The push buttons DOWN/UP must be pressed during the entire maneuver.
Off: Automatic functioning.
(OFF)
Cvar
Enable or disable code programmable transmitters.
On: Radio receiver enabled only for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning
and Dip Switch).
(ON)
REM
Enable or disable the transmitter remote learning (see the paragraph of transmitter remote
learning)
On: enable remote learning
Off: disable remote learning
(ON)
16
RADIO (
RAD
)
MENU
FUNCTION
PP1
Selecting this function the receiver waits for (push) a transmitter code to be assigned to the step by step bollard 1.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
PP2
Selecting this function the receiver waits for (push) a transmitter code to be assigned to the step by step function for
the bollard 2.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
Dovn
Selecting this function the receiver waits for (Push) a transmitter code to be assigned to the function DOWN (both
bollards)
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
vp
Selecting this function the receiver waits for (push) of a transmitter code to be assigned to the function UP (both
bollards)
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
CLR
By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
RTR
The memory of the receiver is entirely erased. Confirmation for the operation is asked.
By selecting this function, the receiver waits for (Push) the GPM key to be pressed again to confirm the operation.
At end of erasing, the OK message is displayed
Note: The transmitters are stored in an EPROM memory (Fig.1 -U11), which can be removed and repositioned in a new control unit,
it required.
CYCLES NUMBER (
Nman1
)
Shows number of complete cycles (down + up ) performed by bollards M1.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG>
0012
>>> <PG>
3456
: made 123.456 cycles.
CYCLES NUMBER (
Nman2
)
Shows number of complete cycles (down + up ) performed by bollards M2.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG>
0012
>>> <PG>
3456
: made 123.456 cycles.
RESET (
RES
)
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters
RES
, pressing the <PG> button again resets the control unit.
Note: The transmitters are not erased from the receiver nor is the access password.
All the logics and all the parameters are brought back to default values, it is therefore necessary to repeat the autoset procedure.