Engineer Programming
Page
181
Quick Keys
Parameter
Default
Range
Lamp Times
Specify here the sounder lamp illumination duration.
Lamp Start–Specify here the start time for the sounder lamp to be
activated.
Lamp Stop ––Specify here the stop time for the sounder lamp to be
deactivated.
Proximity Key Reader
This menu enables to define or modify parameters of Proximity Key Reader that can be
connected to the LightSYS as a bus accessory. Up to 8 PKR's can be connected to the LightSYS.
From the menu Select a PKR and press
.
Note
Access to this sub-menu requires that a Proximity Key reader device is installed on your site.
Quick Keys
Parameter
Default
Range
Masking
Specifies the partitions that are controlled by the specified PKR.
Press
to display the partition application screen:
P=1234 KR=1
Y MASK
Use the
key to toggle
Y
/N)to set the partitions.
Control
Use this menu to define controls of the PKR. Scroll the list and use the
key to toggle Y/N for each option. (See page 166)
INSTANT SET?
SHOW READY?
SHOW SET?
SHOW PART SET?
SHOW OMIT?
When done press
to save your settings.
3A Power Supply
This menu enables to define or modify parameters of 3A switched power supply connected to
the LightSYS as a bus accessory. Up to 4 power supplies can be connected to the LightSYS.