Engineer Programming
Page 166
Quick Keys
Parameter
Default
Range
3.
The following display appears:
WME=X: OMIT
BOX TAMPER ?
If the receiver is mounted inside the LightSYS box select
Y
to
omit the box tamper. Confirm with
4.
Repeat the process for the second wireless expander
Proximity Key Reader
To choose/modify a proximity key reader
1.
Through the menu selection, the following display appears:
KEY READER:
ID=01 TYPE=PKR
2.
Use the
or
keys to position the cursor at ID=1 and
type in the Proximity Key Reader ID number as defined by
the dip switches that you set when you installed the module.
3.
With the cursor positioned at the
TYPE
field, use the
key
to toggle and choose the
PKR
option
4.
Press
. The following display appears:
P=1234 KR01
Y... MASK
5.
Use the
or
keys and the
key to assign the
partitions that will be affected by the instant set function
6.
Press
. The following display appears:
Controls: PKR=1
Use the
or
keys to scroll the list and the
key to
toggle and choose the required option
INSTANT SET?
If Yes, the partitions will be set instantly.
If No, the Exit Delay time period will be applied
SHOW READY?
If YES, the ready status will be indicated on the reader.
If No, no ready status indication will be indicated on
the reader
SHOW SET?
If YES, the Set status will be indicated on the reader.