![Ripley Miller FOC-125 Instruction Sheet Download Page 3](http://html1.mh-extra.com/html/ripley/miller-foc-125/miller-foc-125_instruction-sheet_1463887003.webp)
6. Blade replacement
6.2 Remove the stop plate on the back of the tool
with 1.5mm hex wrench
6.3 Unscrew the blade arm locking screw. Move the
slide forward to remove the blade and replace it.
6.4 If the slide locks into the forward position, observe
care and manually unlock it by depressing the catch as
shown. If a part falls into body cavity inaccessibly, follow
cleaning instructions below to remove the base and
retrieve the part.
6.5 Reverse the above steps and re-secure the cleave blade arm, re-secure the cleave blade, re-asseble the stop
plate, side plate and blade guard.
7. Cleaning
7.1 Disassemble the (4) base holding screws located
under the bumper pads
7.2 Remove the base and clean as desired
8. Troubleshooting
If less than desirable cleave
results occur, note some of the possible causes
on this chart.
6.1 Remove the blade guard, side plate and loosen the
cleave blade as noted in Cleave Blade Index
Instructions steps 1-3.