Ripley Miller FOC-125 Instruction Sheet Download Page 3

6. Blade replacement 

6.2 Remove the stop plate on the back of the tool 
with 1.5mm hex wrench     

6.3 Unscrew the blade arm locking screw. Move the  
slide forward to remove the blade and replace it.   

 6.4 If the slide locks into the forward position, observe 
care and manually unlock it by depressing the catch as 
shown. If a part falls into body cavity inaccessibly, follow 
cleaning instructions below to remove the base and 
retrieve the part.         

 6.5 Reverse the above steps and re-secure the cleave blade arm, re-secure the cleave blade, re-asseble the stop 
plate, side plate and blade guard.       

7. Cleaning 

7.1 Disassemble the (4) base holding screws located 
under the bumper pads  

 7.2 Remove the base and clean as desired 

8. Troubleshooting  

If less than desirable cleave 

results occur, note some of the possible causes 
on this chart.   

6.1 Remove the blade guard, side plate and loosen the 
cleave blade as noted in Cleave Blade Index 
Instructions steps 1-3.   

Reviews: