12.2 Working 

with 

batteries 

 
Using batteries in a wrong way may result in danger for personnel, animals or the environment. Check 
information from battery manufacturer for safe installation and operation.  
 
If battery acid contacts skin or clothing, wash immediately with soap and water. If acid contacts eyes, 
immediately flush with running cold water for at least 20 minutes and get medical attention as soon as 
possible. 
 
Never smoke or allow a spark or flame in vicinity of batteries. 
 
Do not drop metal tools on batteries. The resulting spark or short circuit may cause an explosion. 
 
Remove personal metal items such as rings, bracelets, necklaces and watches when working with 
batteries.  
 
 
 

13  Planning and mounting the inverter 
 

This section will provide you information’s about configuring and installing your inverter. Make sure 
that you are aware of local rules and safety measurements. 
 
 

13.1  Required power draw 

 
Before connecting your appliances to the inverter, always check the power draw required. The inverter 
is affordable to supply surge power for a short time, so as to start up electrical equipment such as 
pumps, motors, etc. Some equipment needs more power while starting up. 
 
The inverter is protected against overload and will switch off automatically when overload is applied. 
As ambient temperature is above 20°C the inverters nominal power may be smaller due to reduced 
cooling. 
 
Using the inverter in high altitudes may also reduce nominal power of the inverter because of less heat 
discharge. As a rule of thumb, the reduction of nominal power is approximately 1.5% per 100m eleva-
tion.  
 

 

13.2 Installation 

 
These units must be only installed by qualified, authorized and trained personnel familiar with the 
locally applicable standards and taking into consideration all relevant safety guidelines and measures!   
 
Before installing the unit check for correct DC-Voltage and power level of the inverter.  
 
The Inverter may be installed in any position. Install the inverter in a dry, well ventilated and dust free 
location. It must be installed out of reach for unauthorized personnel especially children’s. Do not in-
stall the inverter in the same compartment as the batteries. 
 
Never use or install the inverter in locations where there is gas or explosive danger! 
 
For proper cooling of the Inverter ensure that the airflow is not obstructed and keep a clearance dis-
tance of 2.5cm to other units. If the inverter is installed in a closed compartment the nominal power 
may be reduced. 
 
In order to keep the battery cables as short as possible  (max. 6m) locate the inverter close to the DC-
Distribution or Battery. Be aware that during charging of batteries an explosive gas can be generated.  
 
 

  

Summary of Contents for Swing Pro 200VA

Page 1: ...Sinewave Inverters SWING pro 200VA and 350VA User s manual...

Page 2: ...take place which is not in accordance with guidelines local rules instruction s or specification s damage may occur All of these matters will lead to loss of war ranty RIPEnergy AG can not accept any...

Page 3: ...ty Information 6 12 1 General information 6 12 2 Working with batteries 7 13 Planning and mounting the inverter 7 13 1 Required power draw 7 13 2 Installation 7 13 3 DC Wiring 8 13 4 AC Wiring 8 13 5...

Page 4: ...oaded from the homepage of RIPEnergy AG These inverters must be only installed by qualified authorized and trained personnel familiar with the locally applicable standards and taking into consideratio...

Page 5: ...aying for costs arising for transport of the unit or damage that arises during the time the unit is unserviceable The general terms of delivery and terms of sale of RIPEnergy AG are valid 8 Unpacking...

Page 6: ...other AC Source may be connected to the inverters AC Output The inverter will be destroyed immediately The enclosure may heat up to 80 C Never obstruct louvers nor place other items on the inverters...

Page 7: ...d will switch off automatically when overload is applied As ambient temperature is above 20 C the inverters nominal power may be smaller due to reduced cooling Using the inverter in high altitudes may...

Page 8: ...dy mounted to DC Cable Do not remove It is for use with cigarette lighter output in your car Check the fuse of your car for correct size 15A Connect the cables with care to the battery inline fuse If...

Page 9: ...e earth terminal of the inverter This is also important for lighting protection 14 Remote control unit The optional available remote control unit enables remote control of the inverter The remote cont...

Page 10: ...tage indicator indicates that the power inverter has shut itself down because its input voltage fell below minimum input voltage 16 4 Over temp protection LED OTP The over temp indicator indicates tha...

Page 11: ...Manual Swing pro doc 11 12 Version 2 18 Technical data 200VA 350VA...

Page 12: ...of inverter reduce the load Note The inverter will switch on automatically if temperature of the inverter is within normal operating temperature range Overload Reduce load Remove unnecessary consumers...

Reviews: