Rinnai New Zealand Limited
RDV3610 Installation Manual: 11658-E
05-10
10
Building the frame
Using the dimension drawing below and the information on pages 5-8, construct a frame.
A 25 mm clearance is required around the unit (sides and back).
IMPORTANT
1100 - 1125 mm
850 mm min.
540 mm min.
Electrical connection
The standard electrical connection is to the right side of the
front of the appliance. If necessary this can be changed by an
electrician to terminate on the left. The appliance must not be
located immediately below a socket outlet (potential fire hazard).
The connection is either direct wired or connected to a power
point within the cavity. A 1500 mm power cord is supplied with a
3-pin plug. This must be connected to a dedicated earthed power
point. The electric isolation switch must be accessible after the ap
-
pliance has been installed.
The electrical cord is not fire rated and should not come into contact with the fire. If the supply
cord is damaged, it must be replaced by a licensed tradesperson. This must be a genuine
replacement part available from Rinnai, part number 6765B.
250 mm
The 540 mm minimum dimension will
give a 25 mm clearance (plus) from the
back of the unit.