Rinnai Tankless Water Heater Installation and Operation Manual
39
Roof Termination
6 in. (152 mm) Maximum
•
Combustion air
must not
be supplied from occupied
spaces of the manufactured home. Access panels,
doors or opening of any kind are not permitted
between the installation enclosure and the inside of
the manufactured home.
•
The installation enclosure must include an exterior
access door incorporating a single opening positioned
a maximum of 6 in. (152 mm) above the lower edge of
the door. The opening in the access door must be
metal with no less than 1/4 in. (6.4 mm) mesh.
•
The water heater is to be secured to the wall of the
manufactured home using the integrated mounting
brackets on the back side of the water heater.
Installation Enclosure with Louvered Door for
Manufactured Home Applications
Use the following chart to identify the minimum required
size of the opening in the access door.
Model
Input Btu/h
Minimum
Required Area
Example Opening
Size (LxH)
RU199i
199,000
200 in
2
(0.129 m
2
)
20 in. x 10 in.
(508 mm x 254 mm)
RU180i
180,000
180 in
2
(0.116 m
2
)
18 in. x 10 in.
(457 mm x 254 mm)
RU160i
160,000
160 in
2
(0.103 m
2
)
16 in. x 10 in.
(406 mm x 254 mm)
RU130i
130,000
130 in
2
(0.0839 m
2
)
13 in. x 10 in.
(330 mm x 254 mm)
Roof Flashing
Top and Bottom
Mounting Brackets
Door
Louvered Opening
PVC Elbow with
Vent Screen
Hot Water Outlet
Cold Water Inlet
Pressure Relief Valve
To Suitable Drain
Gas Supply
Condensate Drain
Manufactured (Mobile) Home
For Installation in a Manufactured Home (Mobile Home)
Non
-
Direct Vent
(Room Air)
2
Pipe Connections on
Bottom of Water Heater
Summary of Contents for REU-N2024FF-US
Page 67: ...Rinnai Tankless Water Heater Installation and Operation Manual 67 6 2 Ladder Diagram...
Page 74: ...74 Rinnai Tankless Water Heater Installation and Operation Manual 7 Notes...
Page 75: ...Rinnai Tankless Water Heater Installation and Operation Manual 75 Notes...
Page 76: ...76 Rinnai Tankless Water Heater Installation and Operation Manual 100000467 05 8 2019...