Rinnai REH-20DT Owner'S Operation And Installation Manual Download Page 4

 

15. 

  CHILDREN AND ADULTS SHOULD BE ALERTED 

TO THE HAZARD OF HIGH SURFACE TEMPERATURES AND 
SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING 
IGNITION. 

16. 

 YOUNG CHILDREN SHOULD BE CAREFULLY 

SUPERVISED WHEN THEY ARE IN THE SAME ROOM 
WITH THE HEATER. 

17.   

LPG CONTAINERS MUST NOT BE INSTALLED 

INDOORS. 

18.   DO NOT INSTALL IN A WINDY AREA. SUCH AS 

FACING A WINDOW OR A DOOR LEADING TO THE 
OUTSIDE. 

19. 

 WARNING: ELECTRICAL GROUNDING INSTRUCTIONS 

OPTIONAL FAN (1) (REH19D-100) IF IT IS PROVIDED, IS 
EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG 
FOR YOUR PROTECTION AGAINST SHOCK HAZARD 
AND SHOULD BE PLUGGED DIRECTLY INTO A 
PROPERLY GROUNDED THREE-PRONG RECEPTACLE. 
(OPTIONAL FAN MODELS) 

20. 

 WARNING: ELECTRICAL GROUNDING INSTRUCTIONS 

OPTIONAL FAN (2) (REH 10-50) IF IT IS PROVIDED, IS 
EQUIPPED WITH A POLARIZED PLUG FOR YOUR 
PROTECTION AGAINST SHOCK HAZARD. IT SHOULD BE 
PLUGGED DIRECTLY INTO A PROPERLY GROUNDED 
POLARIZED RECEPTACLE. (OPTIONAL FAN MODELS) 

2 1 . 

 THI S AP PL IA NCE  MA Y B E  I NS TAL LE D IN AN 

AFTERMARKET* MANUFACTURED (MOBILE) HOME 
WHERE NOT PROHIBITED BY STATE OR LOCAL 
CODES. *AFTERMARKET=COMPLETION OF SALE, NOT 
FOR PURPOSE OF RESALE FROM MANU-
FACTURER. THIS APPLIANCE IS ONLY FOR USE WITH 
THE TYPE OF GAS INDICATED ON THE RATING PLATE. 
THIS APPLIANCE IS NOT CONVERTIBLE FOR USE 
WITH OTHER GASES. 

22. 

  THIS HEATER SHALL NOT BE INSTALLED IN A 

CONFINED SPACE OR UNUSUALLY TIGHT CON-
STRUCTION UNLESS PROVISIONS ARE PROVIDED 
FOR ADEQUATE COMBUSTION AND VENTILATION AIR. 

23. 

 THE NATIONAL FUEL GAS CODE ANSI Z223.1/ 

NFPA54 DEFINES A CONFINED SPACE AS A SPACE 
WHOSE VOLUME IS LESS THAN 50 CUBIC FEET PER 
1,000 BTU PER HOUR (4.8m

3

 PER kW) OF THE 

AGGREGATE INPUT RATING OF ALL APPLIANCES 
INSTALLED IN THAT SPACE AND AN UNCONFINED 
SPACE AS A SPACE WHOSE VOLUME IS NOT LESS 
THAN 50 CUBIC FEET PER 1,000 BTU PER HOUR 
(4.8m3 PER kW) OF THE AGGREGATE INPUT RATING OF 
ALL APPLIANCES INSTALLED IN THAT SPACE. ROOMS 
COMMUNICATING DIRECTLY WITH THE SPACE IN 
WHICH THE APPLIANCES ARE INSTALLED, THROUGH 
OPENINGS NOT FURNISHED WITH DOORS, ARE 
CONSIDERED A PART OF THE UNCONFINED SPACE. 

24.   DO NOT USE THIS ROOM HEATER IF ANY PART HAS 

BEEN UNDER WATER. IMMEDIATELY CALL A 
QUALIFIED SERVICE TECHNICIAN TO INSPECT THE 
ROOM HEATER AND TO REPLACE ANY PART OF THE 
CONTROL SYSTEM AND ANY GAS CONTROL WHICH 
HAS BEEN UNDER WATER. 

25.  THIS APPLIANCE IS INTENDED FOR SUPPLEMENTAL 

HEATING.

 

 