16.   YOUNG CHILDREN SHOULD BE CAREFULLY 

SUPERVISED WHEN THEY ARE IN THE SAME ROOM 
WITH THE HEATER.
 

17. 

 LPG CONTAINERS MUST NOT BE INSTALLED 

INDOORS. 

18 .  DO NOT INSTALL IN A WINDY AREA. SUCH AS 

FACING A WINDOW OR A DOOR LEADING TO THE 
OUTSIDE. 

19.   EQUATOR MODEL NO. REH-6 MAY BE INSTALLED IN 

BATHROOMS ONLY WHERE STATE AND LOCAL 
CODES ALLOW. MUST BE WALL MOUNTED! 

20.   EQUATOR MODELS NO. REH-6 AND REH-1O MAY BE 

INSTALLED IN BEDROOMS ONLY WHERE STATE 
AND LOCAL CODES ALLOW. MUST BE WALL 
MOUNTED! 

21.   DO NOT USE THIS ROOM HEATER IF ANY PART HAS 

BEEN UNDER WATER. IMMEDIATELY CALL A 
QUALIFIED SERVICE TECHNICIAN TO INSPECT THE 
ROOM HEATER AND TO REPLACE ANY PART OF 
THE CONTROL SYSTEM AND ANY GAS CONTROL 
WHICH HAS BEEN UNDER WATER. 

22.   WARNING: ELECTRICAL GROUNDING INSTRUCTIONS 

OPTIONAL FAN (1) (REH 18-60) IF IT IS PROVIDED IS 
EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG 
FOR YOUR PROTECTION AGAINST SHOCK HAZARD 
AND SHOULD SE PLUGGED DIRECTLY INTO A 
PROPERLY GROUNDED THREE-PRONG RECEPTACLE. 
(OPTIONAL FAN MODELS) 

23. 

  WARNING: ELECTRICAL GROUNDING INSTRUCTIONS 

OPTIONAL. FAN (2) (REH 10-50) IF IT IS PROVIDED IS 
EQUIPPED WITH A POLARIZED PLUG FOR YOUR 
PROTECTION AGAINST SHOCK HAZARD. IT SHOULD BE 
PLUGGED DIRECTLY INTO A PROPERLY GROUNDED 
POLARIZED RECEPTACLE. (OPTIONAL FAN MODELS) 

24. 

 THIS APPLIANCE MAY BE INSTALLED IN AN 

AFTERMARKET* MANUFACTURED (MOBILE) HOME 
WHERE NOT PROHIBITED BY STATE OR LOCAL 
CODES. *AFTERMARKET=COMPLETION OF SALE. 
NOT FOR PURPOSE OF RESALE FROM MANU-
FACTURER. THIS APPLIANCE IS ONLY FOR USE 
WITH THE TYPE OF GAS INDICATED ON THE 
RATING PLATE. THIS APPLIANCE IS NOT CON-
VERTIBLE FOR USE WITH OTHER GASES. 

25 

.  THIS HEATER SHALL NOT BE INSTALLED IN A 

CONFINED SPACE OR UNUSUALLY TIGHT CON-
STRUCTION UNLESS PROVISIONS ARE PROVIDED 
FOR ADEQUATE COMBUSTION AND VENTILATION 
AIR. 

26. 

  THE NATIONAL FUEL GAS CODE ANSI Z223.1/ 

NFPA54 DEFINES A CONFINED SPACE AS A SPACE 
WHOSE VOLUME IS LESS THAN 50 CUBIC FEET PER 
1,000 BTU PER HOUR (4.8m

3

 PER kW) OF THE 

AGGREGATE INPUT RATING OF ALL APPLIANCES 
INSTALLED IN THAT SPACE AND AN UNCONFINED 
SPACE AS A SPACE WHOSE VOLUME IS NOT LESS 
THAN 50 CUBIC FEET PER 1,000 BTU PER HOUR 
(4.8m

3

 PER kW) OF THE AGGREGATE INPUT RATING 

OF ALL APPLIANCES INSTALLED IN THAT SPACE. 
ROOMS COMMUNICATING DIRECTLY WITH THE 
SPACE IN WHICH THE APPLIANCES ARE 
INSTALLED, THROUGH OPENINGS NOT FURNISHED 
WITH DOORS, ARE CONSIDERED A PART OF THE 
UNCONFINED SPACE. 

27. 

THIS APPLIANCE IS INTENDED FOR 
SUPPLEMENTAL HEATING.

 