Recess Box RBOX05 (fully recessed) / RBOX02F (semi-recessed) fits these Rinnai Water Heaters:

INFINITY 32 ENVIRO PLUS

HD210e

INFINITY ENVIRO 32

INFINITY ENVIRO 26

REU-N3237W

REU-N3237WC

REU-KM3237WD

REU-KM2635WD

INSTALLATION METHOD

1. 

Preparation of opening in brickwork:
Height 1020–1050mm, width 495–530mm, minimum depth for a fully recessed installation is 230mm and the 

minimum depth for a semi-recessed installation is 140mm. (If the depth is less than 140mm the box is to be 

installed with the semi-recessed frame RBOX02F).
The Rinnai Recessed box can either be fitted as the brickwork is being laid using the fold out brick ties to 

secure the box, or in an existing installation, cut an opening in the brickwork and fix the box by drilling holes 

in the sides and fix in position with suitable flush headed masonry anchors.

2. 

Semi-Recessed  installation  using  (RBOX02F).  Assemble  the  frame  components  with  screws  supplied, 

utilising the pre-drilled holes located in each corner of the frame components. Slide the assembled frame 

onto the recess box from the rear and secure to the outer frame flange with screws supplied, utilising the pre-

drilled holes 2 of each are located on each side.

3. 

The gas, cold water inlet and hot water outlet pipes can be brought through the pipe entry holes in the bottom 

panel of the box.

IMPORTANT

The Rinnai water heater serial number and model number on the data plate located on the left 

hand side of the appliance, and 

MUST

 be copied to the sticker on the inside of the access panel. 

The serial number is needed for any warranty or service work.

4. 

Secure the bracket with the 5mm stud inside the top of the recess box. Facing the stud to the front of the 

recces box.

5. 

Each recess box is supplied with a right-angle bracket that has 3 small holes on the horizontal tab and a key-

way on the vertical tab. This bracket is to attach the appliance to the 5mm stud in the top of the recess box. 

Remove the three screws located on the top of the water heater and use these to fix the bracket to the top of 

the water heater.

6. 

Hang the water heater on the top bracket over the stud in the top of the recess box and secure with a suitable 

fastener.

7. 

Ensure the lower bracket is located on the 5mm stud on the back panel of the recess box and secure with a 

suitable fastener.

8. 

When fitting the front access panel use a screw driver to 

bend out the tab retaining slots to 90° as shown in Fig. 1.

9.  An approved weatherproof electrical GPO can be fitted 

either inside the recess box, or can be fitted adjacent 

to with the power lead brought through the gap at the 

bottom of the access cover.

10. 

Follow the Testing and Commissioning Procedure contained in the Commissioning Instructions located in the 

pouch behind the front panel of the water heater unit.

11. 

Seal all gaps inside the recess box with Silicon Sealant to prevent water from entering the wall cavity.

12. 

Tighten nuts to secure the appliance.

13. 

Ensure the warning sticker on the front panel is visible when the appliance is installed.

If you require any further information, please contact Rinnai.