32
|
Ember Installation Guide: 12890-A 01-17
Horizontal terminations (mock chimney)
Important notes
t
For the horizontal flue terminal to comply with the required flue clearances, and to fit
under a 2.4 m eave, the
maximum the fire can be installed above the floor is 400 mm
.
Check clearances first before installation.
t
The horizontal run of flue pipe must have a 20 mm
rise
for every 1 m
towards
the flue
termination. NEVER allow the flue pipe to run downwards towards the flue terminal. A
downwards slope can trap heat and become a fire hazard.
t
The horizontal flue length must not be greater than the vertical.
Dimensions are in mm unless otherwise stated
Flueing options
400
20
295
255
900 min.
2 m max.
2 m max.
1
2
3
4
3
5 & 6
Important
The horizontal flue length must
not be greater than the vertical.
245-410*
Flue cowl slides depending on wall thickness
590
Unit height
Flue components
1. Ember adaptor (R3653)
Refer p. 30 for clearance to
combustible information for
the Ember adaptor.
2. Mock chimney horizontal
flue kit (R3654)
3. Flue pipe(s) 150-1000 mm
4. Flue elbow 90 ° (R3643)
Max. number of 90 ° bends
= one.
5. Horizontal flashing kit
(R3646)
6. Horizontal wall terminal
(R3650)