background image

R98eASME (V3237W-ASME)  

Type of Appliance 

Rinnai model number 

Operation  

Minimum/Maximum Gas Rate (Input) 

Electrical 

 
Electrical Consumption 

 
 
Ignition System 

Hot Water Capacity 

Temperature 

Temperature (without controller)  

Approved Gas Types 

Installation 

Thermal Efficiency 

Service Connections 

 
 
Water Flow Control 

Minimum/Maximum Water Supply Pressure 

Temperature controlled, continuous flow, gas hot water system 

REU-V3237W-ASME 

Forced combustion 

19,000 - 237,000 BTU/h (Natural Gas or Propane) 

Appliance: 

 

 

AC 120 Volts - 60 Hz 

Controller: 

  DC 

12 

Volts 

Normal 

   72 

watts 

Standby   2 

watts 

Anti-frost protection 

 

116 watts 

Direct electronic ignition 

0.6 to 8.0 GPM (50° F rise) 

0.9 to 9.8 GPM (35° F rise) 

98° - 140° F  

120° F (factory default) 

Natural or Propane (ensure unit matches gas type) 

Outdoor only 

Natural Gas: 85% 

 

Propane: 83% 

Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 

Water flow sensor, electronic water control and by-pass control  

15 - 150 PSI (50 PSI or above is recommended for maximum flow) 

© 2008 Rinnai Corporation 

3237W-ASME SP-1                       4/2008 

FLOW TABLE 

Water Flow Capacity Curve 

 

R

This model has been built in accordance with the requirements of 
the ASME Boiler and Pressure Vessel Code and has received the 
Certificate of Authorization from the National Board.  The heat 
exchanger has the NB and the HLW stamps. 

Reviews: