R94LSe (VB2735WD-US)    

Type of Appliance 

 
Rinnai Model Number 

Operation 

Minimum/Maximum Gas Rate (Input) 

 
Electrical 
 
Electrical Consumption 

 
 
Ignition System 

Hot Water Capacity 

 
 
Temperature 

 
 
Temperature (without remote)  

Approved Gas Types 

Installation 

Energy Factor 

Thermal Efficiency 

Service Connections 

 
Water Flow Control 

Minimum/Maximum Water Supply Pressure 

Temperature controlled, continuous flow, gas hot water system; 
certified for installation in manufactured (mobile) homes 

REU-VB2735WD-US 

Forced combustion 

9,900 - 199,000 BTU/h (Natural Gas)  
10,300 - 199,000 BTU/h (Propane)  

Appliance: 

 

 

AC 120 Volts - 60 Hz 

Controller: 

  DC 

12 

Volts 

Normal 

   49 

watts 

Standby   2 

watts 

Anti-frost protection 

 

104 watts 

Direct electronic ignition 

Minimum flow rate: 0.26 GPM 
Minimum activation flow rate: 0.4 GPM 
Maximum flow rate: 9.4 GPM (35° F rise) 

98° - 120° F  (factory default)  Maximum temperature is selectable at 
120° F or at 140° F;  98° - 185° F available with the MCC-91 
controller for commercial and hydronic applications 

120° F (factory default) 

Natural or Propane (ensure unit matches gas type) 

Outdoor only 

Natural Gas: 0.82 

 

Propane: 0.82 

Natural Gas: 83% 

 

Propane: 83% 

Gas supply: 3/4 inch MNPT 

Cold water inlet: 3/4 inch MNPT 

Hot water outlet: 3/4 inch MNPT 

Water flow sensor, electronic water control device and fixed by-pass 

20 - 150 PSI (recommended 30-80 PSI for maximum performance) 

© 2010 Rinnai Corporation 

R94LSe VB SP                           8/2010 

FLOW TABLE 

Reviews: