Location

NOTE

 

DO NOT

 install water controllers near a heat source, such as a cook top, stove or oven. Heat, 

steam, smoke and hot oil may cause damage. 

 

DO NOT

 install water controllers outdoors unless protection from dust ingress and sunlight 

are provided.

  The  water  controller  set  as  the 

MASTER

  water  controller 

MUST  NOT

  be  installed  in  a 

bathroom.

 

DO NOT 

install water controllers in direct sunlight.

 

DO NOT

 install water controllers against a metal wall unless the wall is earthed in accordance 

with local electrical authority rules.

  Water  controllers 

MUST  NOT

  be  installed  where  chemicals  such  as  benzene,  alcohol, 

turpentine, hydrogen sulphide, ammonia, chlorine or other similar chemicals are in use.

The Water controller is a water resistant device, however excessive exposure to water may result 

in damage to the controller. Durability is improved when positioned outside the shower recess.

 

AVOID

 direct exposure to water or steam as these conditions may cause a malfunction.

 

MUST BE

 installed at least 400 mm above the highest part of a sink, basin or bath.

  When cleaning your water controller use 

ONLY

 a damp cloth and a mild detergent.

Communication Cables

Water controllers operate at an extra low voltage (12 Volts DC) which is supplied from the water heater, a 10 metre 

long communications cable is supplied for connection to the water heater.

ONLY

 Rinnai supplied communication cables may be used. Optional longer communication cabling is available 

from Rinnai.

total) may be terminated. When attaching three or four cables it is necessary to join the cable terminals as follows:
For each pair cut off the existing spade connectors and re-terminate each pair into a new spade connector 

A

 

(spade connectors are available from your local electrical component retailer) so that there are only two sets of 

spade connectors (4 spade connectors in total) to be terminated.

Single  cables  can  be  used 

when  terminating  up  to  two 

communication cables.

Paired cables are to be used 

when  terminating  three  or 

four communication cables.

A

Water Controllers Limitations

An installation can have up to 4 universal MC-601 water controllers.
Deluxe kitchen, bathroom and wireless water controllers are also available and various combinations of universal 

and the deluxe and wireless controllers can be used with the following limitations:

 

can be used with the following limitations:

 

Only 

ONE

 master controller can be installed. This can be a deluxe kitchen, wireless or universal water 

controller (when programmed as a master controller).

NOTE

this is the default setting and can not be changed.

 

Up to 

TWO

 deluxe bathroom water controllers can be installed.

 

The 

FOURTH

 water controller in any installation 

MUST BE

 a wireless or universal.

For more information regarding deluxe kitchen, bathroom and wireless water controllers, contact Rinnai.

INSTALLATION

Summary of Contents for MC-601

Page 1: ...t will deliver Only one MC model water controller can be designated as a Master water controller and this is normally used in the kitchen All the remaining water controllers are designated as Sub water controllers and are for use in bathrooms toilets and laundries The maximum temperature limit for all Sub water controllers is restricted to 50 C to minimise the risk of burns in these areas Each wat...

Page 2: ...l sound muting simply repeat the process CAUTION Always check water temperature at the outlet before use A parent or carer should always check the temperature before a child is placed in contact with hot water Read the section Warning About Hot Water in the Rinnai Continuous Flow Water Heaters Operation Installation Manual Transferring Priority To control the water delivery temperatures when using...

Page 3: ...r connection to the water heater ONLY Rinnai supplied communication cables may be used Optional longer communication cabling is available from Rinnai total may be terminated When attaching three or four cables it is necessary to join the cable terminals as follows For each pair cut off the existing spade connectors and re terminate each pair into a new spade connector A spade connectors are availa...

Page 4: ...he wall and the water controller 6 7 Optional Programming For Universal Water Controllers MC 601 QUESTION 1 Are there four water controllers connected IF YES You will need to activate the fourth water controller as follows STEP 1 For the water controller in the KITCHEN ONLY press and hold the Priority and On Off buttons simultaneously see Fig 1 until a beep is heard approximately 5 seconds STEP 2 ...

Reviews: