- 14 -
OPERATION WITH STANDARD TEMPERATURE CONTROLLERS
To TURN OFF your hot water system
Simply press the ON/OFF button on any
Temperature Controller (where fitted). This will
shut the Infinity down completely including the
Temperature Controller digital displays.
The ON indicator will go out.
If hot water taps are opened when the Infinity is
OFF, cold water will flow from the taps.
Additional SAFETY features
Whilst the hot water tap is open, the following
safety features apply.
Temperature selection cannot be transferred.
Water temperature can only be adjusted between
37
°
C and 43
°
C.
The Kitchen and Bathroom Control cannot be
turned ON.
O N / O F
F
ON
The temperature of outgoing hot water is constantly monitored by a built-in sensor. If the
temperature of the outgoing hot water rises to more than 3
°
C above the selected temperature
shown on the Digital Monitor or the pre-set limit when Temperature Controllers are not fitted,
the burner will automatically go out. The red operation indicator will also go out. The burner
will ignite again once the outgoing hot water temperature falls to that shown on the Digital
Monitor (or the pre-set limit).
NOTE