10
TECHNICAL DETAILS
Infinity Model
Infinity 20e
Infinity 16e
Units
Installation
External
External
Nat Gas Press Low
1.8
1.8
mbar
Nat Gas Press High
9.2
8.8
mb
–
–
–
ar
LPG Press Low
1.9
1.8
mbar
LPG Press High
8.4
8.1
mbar
Height
530
530 mm
Width
350
350 mm
Depth
170
170 mm
Weight
16
15
kg
Flue System
Temp. Range Controllers
37 - 55
40, 43, 50, 55*
65, 75
40, 43, 50, 55*
65, 75,
37 - 55
deg C
Ignition
Direct Electronic Ignition
Gas Consumption Low
Nat Gas
5.6
5.0
kW
LPG
Nat Gas
LPG
5
5.9
.2 kW
Gas Consumption High
44.4
34.7
kW
34.7
44.4
kW
Max Flow raised 33C
15.4
12
L/min
Min Operation Flow
2.4**
L/min
Water Pressure Nom.
1.0 - 8.3
bar
Power Supply
Electric Consumption
55
47
Watts
Forced Exhaust
Temp. Range without
Controllers
* Factory Setting
** Minimum operation flow based on temperature setpoint and
inlet conditions.
deg C
V/Hz
230 / 50