6)
Removal of
Outgoing Water Thermistor
a.
Remove one (1) screw of Heat Exchanger outlet
water tube.
b.
Unlock bracket and pull off inlet water tube. Ensure
O-ring is not lost or damaged.
c.
Remove one (1) screw and pull off outgoing water
thermistor.
7)
Removal of
Transformer
a.
Remove PCB (refer item 2)
b.
Remove two (2) screws and pull off transformer.
8)
Removal of
Manifold and burner
a.
Remove screws (6 + 3) and pull off manifold.
a.
Remove flame rod terminal (yellow)
b.
Remove combustion chamber front panel (6 screws)
c.
Remove two (2) screws and pull off the burner unit.
d.
Remove three (3) screws and pull off damper