background image

 2

LIMITED WARRANTY

RINNAI FIREPLACE HEATER

WHAT IS COVERED?

This Warranty covers any defects in materials or workmanship, subject to the terms stated below.   This
Warranty extends to the original purchaser and subsequent transferees, but only while the product remains at
the site of the original installation.  This Warranty only extends through the first installation of the product and
terminates if the product is moved or reinstalled at a new location.

HOW LONG DOES COVERAGE LAST?

Item

Period of Coverage

All Parts and Components

2 Years from Date of Purchase

WHAT WILL RINNAI DO?

Rinnai will repair or replace the product or any part or component that is defective in materials or workmanship,
except as set forth as follows.  Rinnai will pay reasonable shipping costs, provided you obtain prior authorization
from an Authorized Rinnai Distributor.  Rinnai will not pay labor charges associated with the repair or replacement
of the product or any part or component. All repair parts must be genuine Rinnai parts.  All repairs or replacements
must be performed by an individual or servicing company that has been authorized by Rinnai or its distributor.

Replacement of the product or replacement of the heat exchanger may be authorized by Rinnai only.  Rinnai
does not authorize any person or company to assume for it any obligation or liability in connection with the
replacement of a product or heat exchanger.  If Rinnai determines that repair of a product is not possible,
Rinnai will replace the product with a comparable product, at Rinnai’s discretion.

HOW DO I GET SERVICE?

You must contact an Authorized Distributor or Installer for the repair of a defective product under this Warranty.
Failure to contact an Authorized Distributor or Installer will void the Warranty.  For the name of the Authorized
Distributor or Installer nearest you, please contact your local HVAC dealer or gas service technician, visit the
Rinnai website (www.rinnai.us), call Rinnai at 1-800-621-9419 or write to Rinnai, 103 International Drive, Peachtree
City, Georgia 30269.

Proof of purchase is required.  You can show proof of purchase with a dated sales receipt, or by completing
and mailing the enclosed Warranty registration card within 30 days of purchasing the product.  Please complete
the enclosed Warranty registration card and mail it to Rinnai at the address shown on the card.  Receipt of this
card by Rinnai will constitute proof-of-purchase for this product.  However, return of this Warranty registration
card is not necessary in order to validate this Warranty.

WHAT IS NOT COVERED?

This Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration,
misapplication, force majeure, improper installation, improper maintenance or service, or for any other causes
other than defects in materials or workmanship.  This warranty does not apply to any product whose serial
number or manufacture date has been defaced.

Rinnai is not liable for any special, incidental, indirect or consequential damages that may arise, including
damage to person or property, loss of use, or inconvenience.  Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation may not apply to you.

LIMITATION ON IMPLIED WARRANTIES

Any implied warranties of merchantability and fitness arising under state law are limited in duration to the
period of coverage provided by this limited Warranty, unless the period provided by state law is less.  Some
states do not allow limitations on how long an implied Warranty lasts, so the above limitation may not apply
to you.

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.

Summary of Contents for IB35ETRLC

Page 1: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on...

Page 2: ...the Warranty For the name of the Authorized Distributor or Installer nearest you please contact your local HVAC dealer or gas service technician visit the Rinnai website www rinnai us call Rinnai at...

Page 3: ...your safety read before operating heater 8 Control panel layout 9 Operation 9 Location 13 Venting 15 Gas connection 15 Log installation 16 Testing and commissioning 17 Maintenance instructions 18 Wiri...

Page 4: ...er with forced convection and natural draft flue system Gas Control Electronic control valve Burners Ember bed flame and heat burner Warm Air Discharge Top front louvres Flue Natural draft Approved 4...

Page 5: ...Refer to local gas authority for confirmation of the gas type if you are in doubt Included in the carton Customer operation information IMPORTANT Before using this product please read this manual care...

Page 6: ...nst the appliance 30 DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITUREAND DRAPERIES 31 CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE...

Page 7: ...Flue Termination Fan Combustion System Ignition System Operation Temperature control Electronic thermostat High Low Off Flame picture select option Up Down buttons Temperature range Low 50 F 60 F 80 F...

Page 8: ...uctions If you cannot reach your gas supplier call the fire dept C Use only your hand to push the gas control buttons Never use tools If the buttons will not activate by hand don t try and repair it c...

Page 9: ...ss the ON OFF button OFF then ON again TURNING OFF Simply press the ON OFF button to switch off the unit The ON indicator will go out The convection fan will continue to operate for several minutes af...

Page 10: ...hen the correct hour shows on the Digital Display Confirm that you have selected AM or PM as required a small indicator on the left hand side of the Digital Display indicates the AM PM setting Use the...

Page 11: ...failure the system memory will retain the Timer programs and the clock will stop at the time the power goes off The clock will start again when the power comes back on but the time will be slow by th...

Page 12: ...f the remote control The clip is removed by inserting a coin or similar into the recess in the back of the remote control and sliding downwards The battery must be of type CR 2032 and will only operat...

Page 13: ...at room ventilation complies with local regulations 7 This heater must be mounted on a hearth not less than 2 thick and at least the width and depth of the heater 8 Installation location shall provide...

Page 14: ...ns a zero clearance kit must be used Combustible installation This may require a sheet of non combustible material to be laid under the heater or a layer of cement to be poured on the hearth The firep...

Page 15: ...be installed vertically only If installation prevents this then there must be at least 4 feet of vertical flue before any bends The flue must not fall below horizontal at any stage There must not be m...

Page 16: ...remove the cover A hole is provided on the right hand side of the junction box for a suitable electrical gland to be attached and the electrical supply to pass through 6 There are two wires one black...

Page 17: ...ewdriver and remove excess material Note The ember bed material must be placed after the logs are fitted If the logs are to be removed for any reason the ember bed material must be removed first and r...

Page 18: ...3 It may take approximately 2 hours for the logs to achieve their full flame pattern and glow During the initial burning in period some smoke and smell may be experienced The heater should be run on t...

Page 19: ...polishes to clean the casing while the fire is in operation Do not damage or distort any part of the heater Do not use wet cloth or spray cleaners on burners VENT MAINTENANCE The flue should be inspec...

Page 20: ...not to damage the fiber seal on the perimeter of the glass 4 The glass may be cleaned with a damp sponge and soapy water If the seal is damaged it should be replaced Remove any soot deposit from the l...

Page 21: ...21 WIRING DIAGRAM PCB LAYOUT Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing...

Page 22: ...g up Small soot deposit Normal operation No action required Inadequate fluesystem Log misalignment Call service department agent Incorrect gas pressure Condensationon glass Normal operation Allow fire...

Page 23: ...block Service call Power failure Service call Room temperature sensor faulty ERROR CODES ERROR CODE MESSAGE The Flame Fire ETR has the ability to check its own operation continuously If a fault occur...

Page 24: ...24 EXPLODED DIAGRAMS...

Page 25: ...25...

Page 26: ...AME 23 2 7875 ELECTRODE 23 2 7520 THERMOCOUPLE 24 2 7876 ELECTRODE NUT S I T 25 2 7872 INJECTOR NG 51 NG 2 7873 INJECTOR LPG 31 LP 27 2 7900 ELECTRODE NUT ETR 28 2 7902 SPACER ELECTRODE PILOT 29 2 798...

Page 27: ...N PANEL IBR ETR US 76 1 7601 1 FAN GUIDE TOP NAT IB35ETR 77 1 7613 FAN DIVIDING BRKT RH IB35ETR 78 2 7554 CLIP THERMISTER CP 90125 2 B 79 1 7989 REAR PANEL IBR USA 80 1 7197 REAR TOP PANEL IBR 81 1 71...

Page 28: ...28 INSTALLATION NOTES...

Page 29: ...29 INSTALLATION NOTES...

Page 30: ...30 INSTALLATION NOTES...

Page 31: ...__________________________ Date ___________________ INSTALLATION COMMISSIONING CHECKLIST INSTALLER DETAILS 1 Was a fireplace inspection carried out i e clearances combustibles etc 2 Was a manufactured...

Page 32: ...Part Number 7919B zx...

Reviews: