Rinnai 10
HOTFLO (HFE Series) Electric Storage Water Heater OIM
APPLIANCE COMPONENTS
NOTE
*
Removalandconnectionbyqualifiedpersons
ONLY
,inaccordancewithAS/NZS3000
Valveswithpressureratingsotherthanspecifiedareunsuitableand
MUST NOT
beused.
WATERHEATER-locatedclosesttomostfrequentlyusedoutlet-Accessforserviceinthe
installed position.
2
1
3
5
4
6
7
8
12
13
10
1
9
2
3
4
5
6
7
8
9
10
11
12
13
14
14
11
THERMOSTAT COVER - ELECTRICAL SUPPLY CONNECTION *
Removal & connection by qualified persons only, in accordance with
AS/NZS 3000
DATA AND WARNING LABELS
LEFT COLD WATER INLET
Connection RP 3/4" / 20mm
LEFT HOT WATER OUTLET
Connection RP 3/4" / 20mm, use a union connection and Insulate Hot water pipe
PTR VALVE DRAIN PIPE (Supplied by Installer)
Copper only Drain in Accordance with AS/NZS 3500.4
THERMOSTAT COVER (Twin element models only) *
Removal by qualified persons only.
DUPLICATE PTR VALVE CONNECTION (25 and 50 litre models only)
PTR VALVE CONNECTION
RP 3/4" / 20mm Use supplied PTR Valve with 1/2" Reducing Bush
ANODE CAP
DUPLICATE COLD WATER INLET
SAFE TRAY & DRAIN (Not supplied).
May be required to avoid property damage in accordance with AS/NZS 3500.4
WATER HEATER SUPPORT
In accordance with AS/NZS 3500.4
DUPLICATE HOT WATER OUTLET
DUPLICATE PTR VALVE DRAIN PIPE (Supplied by Installer)
SPECIFICATIONS