Rinnai HOTFLO EHFA 250 Installation Manual Download Page 8

Rinnai 

EHFA/EHFD HW IM

ANODE

The water heater is fitted with a sacrificial anode to extend it’s life. It will slowly dissipate whilst protecting the 

cylinder� The life of the water heater may be extended by arranging for an authorised person to inspect the anode 

and replace it if required. It is recommended that the anode be inspected at least every 5 years. The factory fitted 

Rinnai anode is Magnesium based� This anode is suitable when the total dissolved solids (TDS) content in the 

water supply does not exceed 600 mg/L, which is the case in most areas� In areas where the total dissolved solids 

(TDS) content in the water supply exceeds 600 mg/L the Rinnai aluminium based anode is required�

WATER QUALITY

The water quality of most public supplies is suitable for the water heating system� The water quality from bore 

wells is generally unsuitable for the water heating system� Refer to the ‘Warranty Conditions’ for water quality 

parameters and how they affect the warranty conditions� If in doubt about the water quality, have it checked against 

the parameters listed in the warranty conditions� If sludge or foreign matter is present in the water supply, a suitable 

strainer filter should be incorporated in the water supply to the system.

OPERATIONAL OVERVIEW

(How the hot water system works)

Single Element Model: 

A vitreous enamel lined steel cylinder stores water which is heated by a single 

thermostatically controlled heating element, located at the base of the cylinder� The water heater connects directly 

to the mains water supply� The heating element can be connected to a Continuous or Off-Peak electricity supply� 

The continuous supply is appropriate when the water heater capacity is less than the daily usage of hot water� The 

Off-Peak supply is appropriate when the water heater capacity exceeds the daily usage of hot water� The Off-Peak 

supply allows heating only for set periods and a volume of water sufficient for daily usage is heated during the set 

period and stored� The Off-Peak supply is usually cheaper� Electricity supply types and tariffs vary according to the 

local electricity authority�

Twin Element Model:

 A vitreous enamel lined steel cylinder stores water which is heated by a twin thermostatically 

controlled heating elements, one element is located at the base of the cylinder, while the other is located near the 

top� The water heater connects directly to the mains water supply� The bottom heating element heats the whole 

contents of cylinder and Top heating element (booster) only operates during the high demand periods to heat the 

upper portion of the contents of the cylinder� The two heating elements are wired for non-simultaneous operation, 

so that only one heating element can operate at a time� The bottom heating element can be connected to an 

Off-Peak electricity supply, and the top heating element to a continuous electricity supply�

Turning Water Heating System ‘OFF’

If the water heater is not going to be used for only a few days, we suggest you leave it switched on� If it is necessary 

to switch off the water heater, the switch is usually marked and located in the electricity meter box of the building�

Turning Water Heating System ‘ON’

Switch on the electric supply to the heating elements� The switch is usually marked and located in the electricity 

meter box of the building� Water heating will now occur as required� It may take a number of hours before hot water 

is available�

DRAINING 

WARNING

Draining

MUST BE 

carriedoutbyaqualifiedperson.

Watermaybe

HOT

 during draining.

Drain the water heater as follows:
1�  Isolate or turn ‘OFF’ the water heater at the electricity supply�
2�  Close the cold water isolation valve at the inlet to the water heater�
3�  Close all hot water taps�
4�  Operate the PTR valve easing gear - gently� Operating the PTR valve easing gear will relieve the pressure 

in the water heater�

5�  Undo the cold water inlet union� Attach a hose to the water heater side of the union� Let the other end of the 

hose go to a drain�

6�  Operate the PTR valve easing gear again� This allows air into the water heater and will result in water draining 

through the hose�

IMPORTANT INFORMATION

Summary of Contents for HOTFLO EHFA 250

Page 1: ...ZS 3500 4 Plumbing and Drainage Heated Water Services All local regulatory requirements including all local OH S requirements This appliance must be installed maintained and removed by a Qualified Per...

Page 2: ...Rinnai 2 EHFA EHFD HW IM...

Page 3: ...cifications 11 Installation Methods 12 Hot Water Plumbing System Example No TLD 12 Hot Water Plumbing System Example With TLD 12 Hot Water Plumbing system Example Flow Return Pipe Work No TLD 13 Hot W...

Page 4: ...Rinnai 4 EHFA EHFD HW IM This page is intentionally blank...

Page 5: ...ons For continued safety of this appliance it must be installed operated and maintained in accordance with the manufacturer s instructions This appliance is heavy use 2 people or mechanical lifting de...

Page 6: ...ING The thermostat setting must only be adjusted by an Electrician or other suitably qualified trades person The access cover to the element and thermostat must only be removed by an Electrician or ot...

Page 7: ...son It is normal for the PTR valve to release a small quantity of water through the drain pipe during heating If the valve dribbles or leaks continuously try easing the valve gear for a few seconds Th...

Page 8: ...et period and stored The Off Peak supply is usually cheaper Electricity supply types and tariffs vary according to the local electricity authority Twin Element Model A vitreous enamel lined steel cyli...

Page 9: ...innai to discuss adjusting the thermostat No water from the hot tap Restriction in the hot tap or failure of the cold water supply to the heater Check for water flow at the other hot taps and that the...

Page 10: ...mm use supplied PTR Valve 8 Anode cap 9 Right hand duplicate hot water outlet Connection RP 3 4 20mm use a union connection and insulate hot water pipe 10 Right hand duplicate cold water inlet 11 Wate...

Page 11: ...s 680 680 680 Recommended PLV pressure rating 500 500 500 ECV Not Fitted kPa Fit PLV if mains pressure exceeds 800 800 800 Recommended PLV pressure rating 500 500 500 Rated Capacity Hot Water Litres l...

Page 12: ...Isolating Valve Isolating Valve PLV ECV OR WATER HEATER Non return Valve COLD SUPPLY Non return Valve Non return Valve WATER HEATER Temperature Limiting Device TLD Non return Valve PTR VALVE Supplied...

Page 13: ...RETURN PIPE WORK WITH TLD COLD SUPPLY Isolating Valve ECV TO DRAIN Non return Valve PLV KITCHEN LAUNDRY NON TEMPERED SUPPLY BATHROOM ENSUITE TO DRAIN PTR VALVE Supplied WATER HEATER Not Supplied Non...

Page 14: ...cur as a result of water leakage the water heater MUST BE installed with a safe tray overflow tray and drain Construction installation and draining of the safe tray MUST comply with local regulatory r...

Page 15: ...ations WARNING Valves with pressure ratings other than specified MUST NOT be used An isolation valve and non return valve MUST BE fitted in the cold water supply to the water heater so the water heate...

Page 16: ...alve outlet in accordance with the section Relief Valve Drain Lines on the bottom of page 16 The valve body MUST BE insulated in accordance with local regulatory requirements and AS NZS 3500 4 to opti...

Page 17: ...e local electricity supplier The Off Peak overnight is usually the most economical for the customer Electrical Connections WARNING The water heater MUST BE filled with water prior to connection to the...

Page 18: ...e access cover to the element and thermostat The access cover to the element and thermostat MUST ONLY BE removed by an Electrician or other suitably qualified trades person The thermostat setting MUST...

Page 19: ...orced out of the taps 3 Close each tap when water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Connect the water heater to the electricity supply an...

Page 20: ...our National Help Line Rinnai recommends that this appliance be serviced every year Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales and Service Na...

Reviews: