TEMPERATURE CONTROLS 

Remote  temperature  controllers  provide  control  over  the  water  temperature.  Rinnai  water 
heaters can be operated with 1, 2, 3, 4 or no temperature controllers. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
The 

MC-91-3A 

controller can be locked by pressing the Transfer button and the 

up-button together for 5 seconds. A beep will sound confirming that the controller 
is locked. The display will alternately show “LOC”, the temperature setting, and a 
diagnostic code if one has been activated. All of the controllers in the system are 
also locked. 

 

Each time a button is pressed, a BEEP will sound. The BEEP sound 
can  be  muted  by  depressing  the  Temperature  Controller  Up  and 
Down  buttons  simultaneously  for  more  than  5  seconds.  This  can  be 
done  for  each  Temperature  Controller.  To  return  to  original  settings, 
repeat this step. 

Safety features 

 
Whilst    the  hot  water  tap  is  open,  the 
following safety features apply: 
 

 

Temperature  selection  cannot  be 
transferred. 

 

 

The  temperature  setpoint  on  the 
controller  with  priority  can  always  be 
lowered,  but    the  setpoint  can  only  be 
raised to 43°C. 

 

 

Other  controllers  are  unable  to  take 
priority 

or 

change 

the 

delivery 

temperature of the water. 

 

 

If off, the controller cannot be turned on. 

The  temperature  of  the  outgoing 
water  is  constantly  monitored  by 
a built in sensor. 
 
If the temperature of the outgoing 

hot water rises to more than 3ºC above the 
selected  temperature shown  on  the  digital 
display, or the preset limit if controllers are 
not  fitted,  the  burner  will  automatically  go 
out. 
 
The red “In Use” indicator will also go out. 
 
The  burner  will  ignite  again  once  the 
outgoing hot water temperature falls to that 
shown on the digital display (or the pre-set 
limit of the Rinnai HDC heater). 

NOTE

NOTE

NOTE

Summary of Contents for HD55e Low NOx

Page 1: ...FUDHD E HDC 1600i Low NOx REU KBM3237WDHD E HDC 1600e Low NOx Continuous Flow Water Heater Important Read these instructions carefully before attempting installation or use of this appliance All work...

Page 2: ...022 Date of Issue 20 01 2014 Last revision 02 02 2010 Quality System Standard ISO 9001 2008 The Design Development and Manufacture of Gas Water Heating Appliances done under Rinnai s Quality Managemen...

Page 3: ...ATER HEATER 21 OPERATION 22 MAIN COMPONENTS 23 INSTALLATION INSTRUCTIONS 24 FLUE REQUIREMENTS 28 CONDENSATE DISPOSAL 32 TEMPERATURE CONTROLS 34 EZ CONNECT 36 TESTING 37 GAS PRESSURE SETTING 38 DIP SWI...

Page 4: ...s be used for these locations where possible The water heater venting and vent termination s should not be installed in any areas where the air may contain these corrosive compounds If it is necessary...

Page 5: ...w the selected temperature The burner lights automatically when the hot water tap is opened and extinguishes when the tap is closed IGNITION IS ELECTRONIC so there is no pilot light When the hot water...

Page 6: ...cause severe burns instantly or even death from scalding Children disabled and the elderly are at the highest risk of being scalded by excessively hot water Always test the temperature of the water be...

Page 7: ...water supply Keep flammable materials trees shrubs chemicals etc away from the flue outlet terminal Do not spray water into flue terminal Do not touch the flue outlet Do not insert objects into the f...

Page 8: ...to a safe level Water temperatures above 50 C can cause severe burns instantly such scalding may even result in death Those most at risk are children disabled elderly and the infirm Hot water at 65 C...

Page 9: ...38 39 40 41 42 43 44 45 46 48 50 C Master Universal Controller MC 91 37 38 39 40 41 42 43 44 45 46 48 50 55 C 60 65 C 75 C HD Deluxe Bathroom Controller BC 100V Hot Water Delivery 37 38 39 40 41 42 4...

Page 10: ...urn to original settings repeat this step Safety features Whilst the hot water tap is open the following safety features apply Temperature selection cannot be transferred The temperature setpoint on t...

Page 11: ...will shut the water heater down completely including the temperature controller digital display The Digital Monitor will go out If hot water taps are opened when the Rinnai HDC is off cold water will...

Page 12: ...r the system Select the desired temperature using the Hot water temp buttons The selected temperature will be displayed on all controller displays This is the water temperature which will be supplied...

Page 13: ...ap in use there may be a variation between the temperature displayed at the controller and the temperature at the tap Do not clean the control with solvents or detergents Use only a soft damp cloth TE...

Page 14: ...ervice call Please quote the code displayed when enquiring about service In all cases you may be able to clear the Error code by turning the hot water tap OFF then ON again If this does not clear the...

Page 15: ...gain If this does not clear the error try pushing the On Off button OFF then ON again If the Error Code still remains contact Rinnai or your nearest service agent for advice Faults caused by insuffici...

Page 16: ...n pump on the return line according to the pump manufacturer installation instructions Install a check valve in the return line as shown in the Plumbing Diagram if one is not integrated into the pump...

Page 17: ...ode operates as follows Less energy consumed due to fewer pump cycles Assumes plumbing is insulated minimal pipe heat loss Pump cycles on every 31 to 79 minutes see table Comfort Mode The Comfort mode...

Page 18: ...ocedure does not reset the heater switch it on and off at its main supply and then go through these steps again If heater is still not working call your local service agent or Rinnai for assistance CA...

Page 19: ...appliance if you are not qualified This can void the warranty If the information in this manual is not followed exactly a fire or explosion could result This manual must be read in its entirety before...

Page 20: ...Department of the Environment Building Standards Scotland Regulations I E E Wiring regulations for electrical installations Gas safety Installation and Use Regulations current issue BS 5546 BS 5440 BS...

Page 21: ...HD range of heaters because they are commercial units If you require controllers in commercial situations they are compatible with the HD range and available from Rinnai UK or your supplier Check that...

Page 22: ...tor starting first Once the air proving is made the Main Solenoid Valve and Change over Solenoid Valves are opened and the Burner is lit by the sparking Igniter Temperature Control Once the Flame Rod...

Page 23: ...circuit is broken This will cease combustion in case of overheat 5 Combustion Fan The combustion fan supplies primary and secondary air to the ceramic plate burner The fan is DC low voltage and the sp...

Page 24: ...e installed in a humid area All Models LPG appliances may not be installed in basements or below ground level The wall or structure on which the heater is mounted must be capable of supporting the wei...

Page 25: ...ion or release fitting on the heater side of the isolation valves An unvented kit to local regulations must be installed in the pipework when the system is closed i e has a flow and return or tank Pos...

Page 26: ...be 20 mbar Natural Gas G20 or 34 5 mbar Propane G31 at the inlet of the appliance with all appliances at high fire Electrical Connection The heater electrical supply must be installed to the latest I...

Page 27: ...applications This information is intended as a guide only it doesn t imply compliance with water or gas installation regulations Components will vary depending on the actual installation Check local...

Page 28: ...of any compounds that cause corrosion of internal components These include corrosive compounds that are found in aerosol sprays detergents bleaches cleaning solvents oil based paints varnishes and re...

Page 29: ...gth for coaxial flueing system is 15m total equivalent length From total equivalent length subtract 2m for each 90 bend max 5 bends and 1 m for each 45 bend There is no limit to the minimum length of...

Page 30: ...e must be installed by a competent authorised person It is the installer s responsibility to ensure that the unit has been installed to all current require ments Location of the appliance flue termina...

Page 31: ...om vertical drain pipe or soil pipe 150mm H From and internal or external corner 300mm I Above ground roof or balcony level 300mm J From surface facing the terminal 600mm K From terminal facing termin...

Page 32: ...nt of discharge Because the condensate is a by product of a gas com bustion it is mildly acid For this reason copper tube and fittings MUST NOT be used as it will corrode Instead Rinnai recommend plas...

Page 33: ...33 CONDENSATE DISPOSAL...

Page 34: ...To bypass this see page 11 Positioning the temperature controls the following points should be taken into account Fit the controls out of reach of children suggested height from the floor 1 5m Avoid p...

Page 35: ...ic power supply 2 Remove the front panel of the appliance 3 Remove the plastic cover from the PCB and electrical connections 4 Thread the cable through the access hole at the base of the unit 5 Connec...

Page 36: ...fluctuations 2 Remove the protective cap from the 3 pin connector marked EZ Connect located in the wiring harness of the Primary Unit Fig 1 3 Plug in the EZ Connect cable The end marked To EZ Connect...

Page 37: ...test point on the inlet to the gas valve The pressure must be within the local defined limits for the type of gas that is being used If the pressure is lower the gas supply is inadequate and the wate...

Page 38: ...dip switches Fig 1 are in the correct position for the type of gas Nat or LPG you are using see page 40 5 Attach pressure gauge to burner test point Fig 2 6 Turn ON the gas supply 7 Turn ON 230V power...

Page 39: ...OFF position Fig 5 17 Close hot water taps and turn OFF the gas supply and 230V power supply 18 Remove pressure gauge and replace sealing screw Turn ON the gas supply and power 19 Operate unit and ch...

Page 40: ...ection indicates position of dip switch OFF ON OFF ON OFF ON Model Type FF Long FF Short W FF Long Common vent1 factory setting factory setting Common vent2 FE Off On Off On Off On Off On SW1 1 SW1 1...

Page 41: ...emotes Connected off on SW1 off on SW1 off on SW1 1 1 1 If the remote is accidentally disconnected the unit would revert to 55 C For safety reasons move the switch no 2 of SW1 to ON 2 2 2 3 3 3 4 4 4...

Page 42: ...ow NOx HDC 1600 e Low NOx Off On SW1 Off On SW1 1 short 1 2 65 C 2 65 C 3 3 4 4 5 5 6 6 7 7 8 8 Off On SW2 Off On SW2 1 short 1 2 FF 2 W 3 3 4 4 5 Auto Reset 5 Auto Reset 6 6 7 7 8 FF 8 W Recirculatio...

Page 43: ...43 DIMENSIONS HDC1600i Low NOx...

Page 44: ...44 DIMENSIONS HDC1600e Low NOx...

Page 45: ...4 4 5 4 01 kW G31 flow normal operating conditions Mm 0 32 0 32 kg hr Gas Consumption Capacities nominal condit Hi net calorific value Hs gross calorific value G20 Nat Gas Input Qn Hi Hs Useful output...

Page 46: ...Load Profile on Energy Label XXL XXL Energy Efficiency Class A A Water Heating Efficiency wh 86 3 86 3 Annual Electricity Consumption AEC kWh annum 20 20 Annual Fuel Consumption AFC GJ annum 22 22 Sec...

Page 47: ...47 FLOW CHART...

Page 48: ...48 WIRING DIAGRAM...

Page 49: ...13V 35 41 Flame Rod 1 D Y FR Over 1 A During Operation Main Power Code F BR BL AC207 264V Ignitor H GY GY AC207 264V During Ignition Heat Exchanger TH C W W 15 C 11 4 14 0k 30 C 6 4 7 8k 45 C 3 6 4 5...

Page 50: ...50 WATER FLOW CHARACTERISTICS...

Page 51: ...51 LETTER OF COMPLIANCE...

Page 52: ...52 CE CERTIFICATE...

Page 53: ...hut off valves Put a bucket under the filter at the bottom of the water heater to catch any water that is contained inside the unit Unscrew the water filter Rinse the filter to remove any debris Insta...

Page 54: ...54 COMMISSIONING SHEET...

Page 55: ...55 SERVICE RECORD...

Page 56: ...edure Flushing the Heat Exchanger Refer to the section on Water Quality to see if your water needs to be treated or conditioned When checking maintenance code history 00 is substituted for LC Snow Acc...

Page 57: ...p inlet into the cleaning solution 7 Open both service valves V1 and V2 on the hot water and cold water lines 8 Operate the pump and allow the vinegar to circulate through the water heater for at leas...

Page 58: ...8 After confirming that the temperature controller is off turn on the gas supply 9 Turn on the temperature controller Running a low volume of water through the water heater to prevent freezing If the...

Page 59: ...es Rinnai water heaters in conjunction with storage tanks Any application that uses Rinnai water heaters in conjunction with a flow return system Water heaters installed as components of centralised b...

Page 60: ...will replace the product with a comparable product at Rinnai s discretion If a component or product returned to Rinnai is found to be free of defects in material or workmanship or damaged by improper...

Page 61: ...531870 Fax 01928 531880 E mail info rinnaiuk com Web www rinnaiuk com CONTACT HEATER DETAILS Model Number _____________________________________________ Serial Number _________________________________...

Page 62: ...62...

Page 63: ...63...

Page 64: ...64 v9 070915RUK U306 1721X02 00...

Reviews: