Rinnai HD200i Installation Manual Download Page 2

Rinnai INFINITY

®

 gas hot water heater flueing shall be 

installed in accordance with:

 

- Manufacturer’s installation instructions

 

- Current AS/NZS 5601.1 Gas Installations

 

- Local regulations and municipal building codes 

Installation, servicing and repair shall be carried out only 

by authorised personnel.

Warning

 

Improper installation, adjustment, alteration, service or 

maintenance can cause property damage, personal injury 

or loss of life.

Important:

For more information about buying, using, and servicing 

of Rinnai appliances call: 0800 RINNAI (0800 746 624)

Rinnai New Zealand Limited  

105 Pavilion Drive, Mangere, Auckland

PO Box 53177, Auckland Airport, Auckland 2150

 

Phone: 

(09) 257 3800

Fax:    

(09) 257 3899 

Email:    

[email protected]

Web:  

www.rinnai.co.nz 

  www.youtube.com/rinnainz

  www.facebook.com/rinnainz

Summary of Contents for HD200i

Page 1: ...eing components outlined in this guide are suitable for the following Rinnai INFINITY models Current models EFi250 REU KM3237FFUD HDi200 REU VR2632FFUG Discontinued models HD200i REU VM2632FFUC HDi200...

Page 2: ...nnel Warning Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Important For more information about buying using and servicin...

Page 3: ...ns and suitability 4 Flueing guidelines 5 Flue spigots and condensate 6 Condensate 6 UV protectors 7 Cutting to size 7 Direct flueing using FFSSKIT 8 Horizontal extension flueing 8 Combination flueing...

Page 4: ...ough the roof Combination flueing Installations using a combination of horizontal and vertical flueing 1 2 4 3 The flueing for internal water heaters is a coaxial design It has a stainless steel inner...

Page 5: ...is required The flue cowl should have a 500 mm clearance from any part of the building This also applies to steeped and pitched roofs which should be clear of the ridge line Lesser clearances may pro...

Page 6: ...nai recommends plastic pipe and fittings such as UPVC or PE Condensate HD200 and XR26 internal models A condensate trap kit FFSSCOND is required for flue lengths over 1 5 m If flueing is less than 1 5...

Page 7: ...tightness will be an issue if the protector is installed inside the decktite Cutting to size Pipes overlap by approximately 37 mm Once joined the effective length reduces by 37 mm This needs to be fac...

Page 8: ...485 mm max HDi200 2 fall 140 mm hole Horizontal extension flueing For installations where the Rinnai INFINITY gas hot water heater is mounted against an internal wall and the flueing needs to be exten...

Page 9: ...lue lengths over 1 5 m Total flue length can be 15 m Combination flueing Combination of vertical and horizontal flueing HDi200 unit will need a condensate trap kit FFSSCOND FFSSROOFCOWL with roof prot...

Page 10: ...90 OFFSET 85 166 66 10 80 5 165 64 5 As a 45 OFFSET 5 176 1 0 8 0 92 85 Condensate trap kit FFSSCOND for the HDi200 Hose is approx 516 mm I D 20 mm End to end approx 180 mm Flue pipe FFSSPIPE1000 can...

Page 11: ...n UV roof protectors shown below for covering and protecting the white flue pipe from UV damage Also includes a flue pipe clamp to support the flue Direct flue kit for horizontal installations FFSSKIT...

Page 12: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz 11748 E 05 15...