Rinnai Granada 252 Operation & Installation Manual Download Page 15

Rinnai 15 

GRANADA 252 - REH-252UCH2 - OIM

CARE & MAINTENANCE

TROUBLE SHOOTING CHECKLIST

Use the following chart to help determine whether a service call is required, however if you are unsure about the 

way your heater is operating, or if you have any other faults or problems, please refer to your installer or a Rinnai 

Customer Care Centre Consultant. See back page for Rinnai contact details.

Problem

Cause

Unit won't ignite

Fan stops when heater is turned of

f.

Takes too long to heat room

Smell of gas

Unit goes out when ignition button is released.

Unit cuts of

f at all settings

Remedy

Not plugged in at power point

l

Plug in and switch on

Power cut/failure

l

l

Investigate cause 

Allow to cool, re-ignite when power is restored

Air in gas pipe (Initial Installation)

l

Purge air (installer)

Gas filter blocked

l

l

Service call

Not pushing ignition button firmly enough

l

l

Push button firmly

Louvre obstructed

l

Remove obstruction

Gas leak

l

Turn off gas. Service call

Room too large

l

Check with retailer

Faulty fan

l

l

Service call

Oxygen depletion system operating

l

Ventilate room

Air in hose

l

Try ignition again

Gas turned off at meter

l

Turn gas on

Automatic fan switch operating

l

Normal operation

SERVICE

This appliance does not contain user serviceable parts and

 MUST ONLY

 be serviced and repaired by an 

authorised person. If the power supply cord or any other component of the heater are damaged, they 

MUST BE

 

replaced by Rinnai or a suitably qualified person.

Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best 

service on your Rinnai appliance. 

Rinnai recommends that this appliance be serviced every 2 years.

 If your 

appliance requires service, please call our National Help Line (contact numbers for which are on the back cover 

of this manual).

NOTE

Service calls for general cleaning, maintenance and wear and tear are not necessarily covered 

under the warranty. Service calls of this nature may be chargeable.

Faults caused by insufficient gas supply, gas quality, installation errors or operation errors are not 

covered by the Rinnai warranty. Refer to separate Warranty Manual for details.

Summary of Contents for Granada 252

Page 1: ...Portable Radiant Convection Gas Space Heater Operation Installation Manual Models Granada 252 REH 252UCH2 ...

Page 2: ... Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained removed and serviced ONLY by an Authorised Person Service and removal must be carried out by an authorised person The installation must also comply with the instructions supplied by Rinnai For continued safety of this appliance it must be installed and maintained in accorda...

Page 3: ...on 11 Operation 12 Connect Gas And Plug Into Power Point 12 To Increase the Heat 13 To Decrease the Heat 13 Fan 13 To Turn the Unit Off 13 Care Maintenance 14 Oxygen Depletion Sensor 14 Outer Case 14 Rinnai Guarantee of Quality 14 Guarantee Information 14 Trouble Shooting Checklist 15 Service 15 Installation Instructions 16 Specifications 16 Unpacking 16 Included in Carton 16 Before Installation 1...

Page 4: ...Rinnai 4 GRANADA 252 REH 252UCH2 OIM This page is intentionally blank ...

Page 5: ... instructions Take care when opening or unpacking this appliance Failure to do so may result in serious injury or product failure DO NOT modify the electrical wiring of this appliance If the power cord is damaged or deteriorated then it must be replaced by an authorised person Failure to do so may result in electric shock fire serious injury or product failure Please keep this instruction booklet ...

Page 6: ...ended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety DO NOT use for any other purpose other than heating The wire dress guard supplied with this appliance must not be permanently removed as it...

Page 7: ...lace articles in front of the louvres DO NOT operate install this heater in areas where painting is taking place or in places such as hairdressing salons where there may be fluff and dust and where aerosols are used DO NOT cover or place articles on or against this appliance DO NOT use or store flammable materials in or near this appliance Keep flammable materials away from heater Combustible mate...

Page 8: ... OFF after use DO NOT remove the Wire Dress Guard The dress guard is fitted to this appliance to reduce the risk of fire or injury from burns and no part of it should be permanently removed For protection of children or the infirm a secondary guard is recommended Heat emanating from the front of the appliance may over time affect the appearance of some materials used for flooring such as carpet vi...

Page 9: ...commended this should be carried out by Rinnai or our agent Flame Failure Sensing System If the flame goes out during operation the flame failure device automatically cuts off the gas supply to the heater To restore the gas supply turn the heater off wait 30 seconds then follow the ignition instructions Tilt Switch If the heater is knocked over the tilt switch will cut off the gas supply To restor...

Page 10: ...omponents listed are present before proceeding with the installation CARTON CONTENTS COMPONENTS DESCRIPTION QUANTITY 1 Granada 252 REH 252UCH2 1 2 Operation and Installation Manual 1 3 Warranty Booklet 1 4 1 5m gas hose with bayonet fitting attached to heater 1 NOTE Installer please note that this item is shipped inside the heater below the gas control on the bottom right hand side of the applianc...

Page 11: ...nce needs service please contact Rinnai refer to the back cover for contact details Rinnai recommend that this appliance be serviced every 2 years FEATURES 1 Fan assisted radiant convection flueless space heater 2 Push button top mounted control for easy operation 3 Electronic automatic ignition 4 Large capacity fan to circulate warm air effectively 5 Two setting fan control to turn the fan on and...

Page 12: ...spark the centre burner will ignite Check that the burner has lit continue to hold the button down for about 15 seconds The spark will continue whilst the button is held down NOTE If the burner does not remain alight push the button again and release it this will return it to the OFF position Wait 30 seconds then repeat the ignition procedure The ignition button must be in the OFF position before ...

Page 13: ... MEDIUM HIGH Granada 252 8 16 25 FAN SWITCH The fan switch has two speed settings and an OFF position This allows you to choose the best conditions for maximum comfort The heater may also be used with the fan off If the fan switch is in the HIGH or LOW position the fan starts automatically when the heater is alight When the heater is turned off the fan stops automatically there is no need to retur...

Page 14: ... OF THEAPPLIANCE WHILE IT IS IN OPERATION The guard is fitted to this appliance to reduce the risk of fire or injury from burns and no part of it should be permanently removed For protection of young children or the infirm a secondary guard is required RINNAI GUARANTEE OF QUALITY As a purchaser of a high quality Rinnai product we provide you with the following guarantee on your new heater Free lab...

Page 15: ... l Check with retailer Faulty fan l l Service call Oxygen depletion system operating l Ventilate room Air in hose l Try ignition again Gas turned off at meter l Turn gas on Automatic fan switch operating l Normal operation SERVICE This appliance does not contain user serviceable parts and MUST ONLY be serviced and repaired by an authorised person If the power supply cord or any other component of ...

Page 16: ...uthority for confirmation of gas type if in doubt Gas type is indicated on the data plate Check room size and ventilation This heater must not be installed in a room smaller than 125m3 Fixed ventilation must conform to local regulations Number and position of vents is for illustrative purposes only For more information on ventilation please refer to the Rinnai website on www rinnai com au DO NOT i...

Page 17: ...O BOOKCASES OR SHELVES Ensure that the area in which the appliance is installed has adequate fixed ventilation this fixed ventilation must be provided as detailed in AS NZS5601 An EARTHED power point and bayonet gas connection must be close enough to where the heater will be used to avoid stretching the connection NOTE After installation checks have been completed connect gas and power and follow ...

Page 18: ...Supplied with approved 1 5m Hose Ignition Electronic Oxygen Depletion System Rinnai ODS Pilot Power Supply 240V 50Hz unit is fitted with a supply lead and 3 pin plug replace only with Rinnai part number 90174772 Fan Tangential 2 speed 24 Watt Rating Data Plate Rear near the gas connection Rinnai are continually updating and improving products therefore specifications are subject to change without ...

Page 19: ...IM SPECIFICATIONS WIRING DIAGRAM DIMENSIONS FAN black black black blue blue blue green green white white blue blue red R NZ AC230V AC240V 50Hz Supply lead must only be replace with Rinnai Part Number 90174772 g y 240 620 541 179 220 182 ...

Page 20: ...l higher from mobile or public phones For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please call our National Help Line Rinnai recommends that this appliance be serviced every 2 years With...

Reviews: