Rinnai Corporation ES08 Manual
13
Fault
Codes
If there is a malfunction the appliance may shut down
as a safety precaution and display a fault code to
assist in diagnosing the problem. The fault code will
flash in the display on the control panel. When making
a service call, this code will assist with diagnosing the
fault.
You may be able to clear the fault code by turning the
heater off and then on again. If the fault code remains
or returns on the next operation, contact Rinnai or your
nearest service agent and arrange for a service call.
[1] Remove any obstructions. The flue needs to be kept clear to expel exhaust gases. If the appliance fails to
operate contact a qualified service agency.
[2] If the fusible link needs replacement, it must be done by a qualified service agency. In addition, the cause of
the overheat needs to be determined. The fusible link is a one use safety device that breaks to shut off the
appliance.
CODE DISPLAYED
FAULT
REMEDY
11 Ignition
Failure
Check that gas is turned ON.
Check that the vent termination is not blocked.
Refer to the Restart Function explanation.
Service call if repeated.
14 Overheat
Clean filter.
Service call if repeated. [1]
16
Room Overheat
Lower room temperature to less than 104°F (40°C).
31
Room Temperature Sensor
Faulty
Service call.
32
33
Overheat Temperature
Sensor Faulty
Service call.
34
49 Sensor
Breakdown
Service
call.
53 Sparker
Failure Service
call.
61
Combustion Fan Failure
Service call.
70
Faulty ON/OFF Switch
Service call.
71 Faulty
Solenoids
Service
call.
72
Faulty Flame Rod
Service call.
73
Communication Error
Turn heater OFF, then ON again.
99
Flue Block
Check around the flue terminal for blockage. [2]
If the appliance fails to ignite, the appliance will attempt ignition after 1 hour. The “Ignition Failure” fault code, 11,
will appear during that hour and disappears after a successful ignition. If ignition fails again, then the fault code
will remain and another attempt to ignite will occur in 1 hour. The fault code is not stored in the fault code history.
If the flame is extinguished during forced combustion then the appliance will attempt ignition after 1 hour. The
“Ignition Failure” fault code, 11, will appear during that hour and disappears after a successful ignition. Forced
combustion takes place for about 15 seconds after ignition. After this time, the temperature control logic controls
the combustion.
If the flame is extinguished (burner combustion failure) while the temperature control logic is operating the
appliance, then the appliance will immediately attempt ignition. No fault code will appear.
Restart
Function
Summary of Contents for ES08
Page 6: ...6 Rinnai Corporation ES08 Manual Getting to know your new ES08 Operating Instructions ...
Page 7: ...Rinnai Corporation ES08 Manual 7 Control Panel All buttons beep when operated ...
Page 24: ...24 Rinnai Corporation ES08 Manual Cut Away Diagram ...
Page 25: ...Rinnai Corporation ES08 Manual 25 Wiring Diagram ...
Page 27: ...Rinnai Corporation ES08 Manual 27 Flow Diagram ...
Page 29: ...Rinnai Corporation ES08 Manual 29 Parts List ...
Page 30: ...30 Rinnai Corporation ES08 Manual Parts List ...
Page 31: ...Rinnai Corporation ES08 Manual 31 Parts List ...
Page 32: ...32 Rinnai Corporation ES08 Manual Parts List ...