– 16 –
LOCATION
Do not flue into natural draught flues or fireplaces,
this unit can only be used with one of the six types
of Rinnai flue kits.
Do not flue unit into other rooms.
Flue terminal must be outside.
When fitting the terminal beneath any ventilation
opening i.e. openable window, inlet to a ventilation
system etc., check that no part of the terminal will
finish within 300mm when measured vertically from
the bottom of such openings. When the terminal
will finish less than 2m above the level of any
ground to which any person has access, a terminal
guard of durable material must be fitted, and these
are available from your supplier.
FLUE SIZES
6 Flue lengths are available.
S
flue suits wall
75
-
115 mm
A
flue suits wall
115
-
240 mm
B
flue suits wall
240
-
400 mm
C
flue suits wall
400
-
600 mm
D
flue suits wall
600
-
800 mm
E
flue suits wall
800
-
1000 mm
25mm spacers are available for wall thickness less
than 75mm.
SNOW AREAS
In areas subject to heavy snowfall, keep snow clear
of flue terminal at all times.
STANDARD INSTALLATION OF FLUE
MANIFOLD.
Diagram below shows minimum clearances and
distances from obstructions. Also check local
regulations.
Flammable
Wall
Non
Flammable
600mm
300mm
Opposite
Wall
Floor
600mm
300mm
Obstruction
300mm
Snow
Side Clearances
FIT BACK COVERS (SIDES ONLY)
Fit back covers (sides only) as shown below.
Engage Lugs
Secure with
Screws