EX22C (RHFE-559FTA)
Rinnai Corporation
• 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
Safety Devices
Venting
Maximum Vent Length
Wall Thickness and
Flue Manifold Kits
(the “A” vent kit is included
with the appliance)
Warranty
Conversion Kit
•
Flame rod detects flame failure; results in auto shutdown to prevent escape
of gas
•
Bi-metal switch, thermal fuse, and thermistor detect overheat condition;
results in auto shutdown
•
3 amp fuse protects against power surge; results in auto shutdown
•
Abnormal spark at time of ignition results in auto shutdown
•
Combustion fan purges any gas from the combustion chamber before
ignition
•
Convection fan continues to run after burner shutdown to cool internal parts
•
Child lock prevents inadvertent operation
•
Appliance shuts down if room reaches 104° F (40° C)
concentric; 3 1/8 inch (80 mm) wall hole
13 feet (4 m) with a maximum of 2 bends; maximum 10 feet (3 m) vertically
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
To natural gas: 204000036
To propane gas: 204000040
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Name
Kit No.
fits walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
10.1 in (257 mm)
3.3 in
(85 mm)
6.8 in
(172 mm)
29.9 in (760 mm)
22.9 in
(582 mm)