SERVICE MAINTENANCE SCHEDULE - DUCTED AIR CONDITIONING SYSTEMS 

Your Rinnai Ducted Air Conditioning System should be maintained annually after the date of installation by a 

qualified licensed technician in accordance with the Schedule below. Failure to do so during the product warranty 

period may void your warranty� This periodic service and maintenance will  prolong the useful life of the unit, and 

help keep it running safely and at optimum efficiency.

Date of 

Installation

 

  /           /

Installed By:

YEAR OF SERVICE

1

2

3

4

5

6

Service Date

  /           /

  /           /

  /           /

  /           /

  /           /

  /           /

Service Company / Technician

Ambient Temperature at CDU (°C)

ELECTRICAL

Wiring, Electrical 

connections

Fan 

Motors

 

Capacitors

 (if Applic)

Printed circuit 

boards

Outdoor unit 

clearances

Outdoor unit 

condensate

 tray

Outdoor unit 

condensate

 drain

Outdoor unit 

fixing

Indoor unit 

clearances

Indoor unit 

condensate

 tray

Indoor unit 

condensate

 drain

Refrigerant charge

Refrigeration

 

connections

Fan 

assemblies

CONTROLS

Thermostat(s)

Zone 

Controls

 (If Applic)

SYSTEM OPERATION

Sequence of 

operation

Return Air Temp - Cooling/ 

Heating

o

C

o

C

o

C

o

C

o

C

o

C

Outlet Air Temp - Cooling / 

Heating

o

C

o

C

o

C

o

C

o

C

o

C

Outdoor unit - Liquid line 

a

P

k

a

P

k

a

P

k

a

P

k

a

P

k

a

P

k

e

r

u

s

s

e

r

p

Outdoor unit - 

Suction

 line 

a

P

k

a

P

k

a

P

k

a

P

k

a

P

k

a

P

k

e

r

u

s

s

e

r

p

Zone 

Operation

 (If Applic)

Ductwork and 

fittings

Return Air grille & 

filters

Airflow

 through 

system

Refrigerant pipework

Safety tray

Zone 

motors

CONSUMABLES **

Capacitors

Filters

Batteries

 (If applic)

Adjusted Part

Cleaned Part 

Replaced Part 

Repaired Part 

Referred to Installer

R

RP

RI

Installation

 and other 

field

-

supplied

 

components

 are not covered by 

Brivis

 Product  Warranty.  

These

 include, but are not limited to, control wiring, 

ducting,

 return air 

filter(s)

 grille, 

register,

 

diffuser,

 zone 

motors,

 

controls/thermostats,

 pipework, fabricated or added 

components

 and refrigerant 

gas

 and electrical 

connections

 to the appliance. 

These

 

should

 be 

inspected

 

as

 they can 

affect

 the performance, reliability and 

safety

 of the 

system.

** 

Units

 contain 

consumable

 

items

 that may require periodic replacement and are not covered by 

Brivis

 product  warranty  (e.g. 

filters,

 

capacitors

 and 

batteries)

ACTION CODES

Inspected - Working Correctly - No 

Action

 Required

MAJOR COMPONENTS

 GENERAL INSTALLATION-RELATED AND 3rd PARTY COMPONENTS (NOT BRIVIS  PRODUCTS)  *

CARE & MAINTENANCE

Summary of Contents for DINLR07Z72

Page 1: ...nce must be installed maintained and removed only by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer s instructions Owner s Manual Ducted Reverse Cycle Inverter Outdoor Units Indoor Units DONSR07Z72 DINLR07Z72 DONSR10Z72 DINLR10Z72 Z721 DONSR12Z72 DINLR12Z72 DONSR14Z72 DINLR14Z72 DONSR17Z72 DINLR17Z72 Rinnai Ducted...

Page 2: ...Rinnai 2 Ducted Reverse Cycle Inverter OM This page is intentionally blank ...

Page 3: ...aintenance Pre Season Inspection 7 Installation Record Installer Details 8 Installation Record System Details 8 Customer care Program 8 Service Maintenance Schedule Ducted Air Conditioning Systems 9 Save A Service Call 10 General User Guide 12 Operation and Maintenance 12 Operating your system 12 Cooling Cycle 13 Heating Cycle 13 Zoned Systems 13 Performing Routine Maintenance 13 Checking The Air ...

Page 4: ...l surface or where there may be a danger of it falling It may result in death serious injury or product failure DO NOT install the outdoor unit where noise may cause nuisance DO NOT install the outdoor unit where it will be exposed to sea wind salt spray as this will reduce durability ACHIEVING OPTIMAL PERFORMANCE For optimal performance ensure to use the air conditioner within the following tempe...

Page 5: ...rate the appliance if it has been submerged into water due to flooding contact a service agent Failure to do so may result in electric shock fire serious injury or product failure This appliance is NOT intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern...

Page 6: ...e you perform any maintenance otherwise it may cause electric shock When removing filter do not touch metal parts in the unit The sharp metal edges can cut you DO NOT use chemicals or chemically treated cloths to clean the filters DO NOT use benzene paint thinners polishing powder or other solvents They can cause the plastic surface to crack or deform NEVER use water that is hotter than 40 C when ...

Page 7: ... Fan function until unit dries out completely Turn off the unit and disconnect the power Remove batteries from remote control MAINTENANCE PRE SEASON INSPECTION After long periods of non use or before periods of frequent use do the following Check for damaged wires Clean all filters Check for leaks Replace batteries Make sure nothing is blocking all air inlets and outlets of both the indoor or outd...

Page 8: ...__________________ Serial Number Outdoor Unit ________________________________________________________________ Installation Address ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ CUSTOMER CARE PROGRAM Please ensure you register your product warranty on...

Page 9: ...g Heating o C o C o C o C o C o C Outlet Air Temp Cooling Heating o C o C o C o C o C o C Outdoor unit Liquid line a P k a P k a P k a P k a P k a P k e r u s s e r p Outdoor unit Suction line a P k a P k a P k a P k a P k a P k e r u s s e r p Zone Operation If Applic Ductwork and fittings Return Air grille filters Airflow through system Refrigerant pipework Safety tray Zone motors CONSUMABLES Capac...

Page 10: ...he indoor unit and is normal Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units Low hissing sound when the system starts has just stopped running or is defrosting This noise is normal and is caused by the refrigerant gas stopping or changing direction The outdoor unit mak...

Page 11: ...to the cooling heating or auto The air inlet or outlet of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Too many sources of heat in the room people ...

Page 12: ... have unrestricted airflow Do not cover the unit lean any thing against it or stand upon it Do not allow grass clippings leaves or other debris to accumulate around or on top of the unit Maintain a minimum of 300mm clearance between the outdoor unit and tall grass shrubs vines etc Your Thermostat Controller is the control centre for your system Please familiarise yourself with its specific operati...

Page 13: ... may condense into a mist in the cold outdoor air ZONED SYSTEMS Some home comfort systems are designed to operate on a zoned basis only i e they are not designed to heat and or cool the entire home or space at one time Generally a zoned system will be designed by your Installer for your specific requirements Your particular zoning configuration and the basis of design should be specified and detai...

Page 14: ...he FCU should be maintained at a position that ensures condensate drainage from the unit In an attic space ideally the unit will be easily and safely accessible from the ceiling access panel have a suitable catwalk and platform and if necessary a service light The outdoor Condensing Unit CDU requires adequate support to ensure it is level CDUs generate condensate water in the heating mode dependin...

Page 15: ... the law requires special collection and treatment DO NOT dispose of this product as household waste or unsorted municipal waste IMPORTANT Special notice Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment Hazardous substances may leak into the ground water and enter the food chain GENERAL USER GUIDE ...

Page 16: ...ans 8 30am to 5 00pm Monday to Friday excluding public holidays 7 Operating Installation Instructions means the user manual or other documentation which provides detailed instructions on the proper operation and maintenance of the Product 8 Other Applications means any Product used for purposes other than Residential Light Commercial Applications OtherApplications may include but are not limited t...

Page 17: ... performed during Normal Business Hours by anAuthorised Service Representative Repair by persons other than anAuthorised Service Representatives may void the Warranty 2 4 Alternatively to clause 2 3 above Rinnai can at its discretion elect to pay you an amount equivalent to the cost of repairing or replacing the Product 2 5 If Rinnai provides you with either the replacement costs or replacement pr...

Page 18: ...or poor external electrical wiring incorrect or faulty power supply voltage fluctuations over voltage transients or electromagnetic interference inadequate or faulty gas drainage services or water services including water pressure and non potable water d damage problems or failure caused by acts of God fire wind lightning flood storm hail storm fallout vandalism earthquake war civil insurrection m...

Page 19: ...t freight charges in transit insurance expenses or travelling costs without written authorisation from Rinnai Rinnai will not reimburse the Purchaser for such costs 6 3 The Purchaser must pay all costs and expenses in respect of a any service call out fee if the Product is not accessible for service b making the Product accessible for service for example restricted access or working at heights or ...

Page 20: ...t this appliance be serviced at least every 2 years With our policy of continuous improvement we reserve the right to change or discontinue at any time specifications or designs without notice Australia Pty Ltd ABN 74 005 138 769 100 Atlantic Drive Keysborough Victoria 3173 P O Box 460 Braeside Victoria 3195 AU45204 Product Sales Service National Help Line Tel 1300 555 545 Fax 1300 555 655 Monday ...

Reviews: