background image

 

For safe, reliable operation and optimum performance 
this appliance must be installed, operated and 
maintained in accordance with these instructions.  

Read these instructions thoroughly before attempting 
installation and operation.  

Keep these instructions handy for future reference.  

Operation & Installation Manual

Electric Panel Heaters

Models: DEPH-10DTW, DEPH-15DTW & DEPH-22DTW

Summary of Contents for DEPH-10DTW

Page 1: ... operated and maintained in accordance with these instructions Read these instructions thoroughly before attempting installation and operation Keep these instructions handy for future reference Operation Installation Manual Electric Panel Heaters Models DEPH 10DTW DEPH 15DTW DEPH 22DTW ...

Page 2: ...DEPH_OIM BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE REQUIREMENTS FEATURES AND OPERATION OF YOUR NEW APPLIANCE ...

Page 3: ...THE HEATER 7 GENERAL DESIGN LAYOUT 7 CONNECTING THE POWER 8 OPERATION 8 DELAY OFF TIMER OPERATION 9 ANTI FROST PROTECTION FUNCTION 10 ELECTRONIC LOCK FUNCTION 10 TILT SWITCH 10 CARE AND MAINTENANCE 11 CARE OF THE HEATER 11 ERROR CODES 11 SERVICE AND REPAIR 11 DISPOSAL 11 INSTALLATION 12 GENERAL 12 WALL INSTALLATION 12 FREESTANDING INSTALLATION 14 CONTACT INFORMATION 16 TABLE OF CONTENTS ...

Page 4: ...Rinnai 4 DEPH_OIM This page is intentionally blank ...

Page 5: ...vice agents 5 Where it is found that there is no fault with the appliance and the issue is related to the installation or is due to the failure of electricity supply FEATURES This heater incorporates the following design features SPECIFICATIONS DIY Installation This heater is suitable for Do It Yourself installation Silent Operation Electric element operation eliminates fan noise Draft Free Non fa...

Page 6: ...d physical sensory or mental capabilities to sleep directly in front of the heater DO NOT allow children to post articles into the louvres of the heater The electrical cord must not come into contact with the heated parts of the heater DO NOT use power boards or double adaptors with this heater DO NOT coil or bundle the electric cord to reduce it s length as overheating of the cord may occur which...

Page 7: ...howing delay timer related settings Tilt warning indicator and 30min interval digit for timer Vent warm air discharge 240 Volt power cord plug Air inlets Optional castors for floor mounting see INSTALLATION on page 14 for installation options Optional brackets for wall mounting see INSTALLATION on pages 12 14 for installation options This heater features audible chimes On start up a set of rising ...

Page 8: ...conds The selected temperature will now be set and displayed If the selected temperature is above that of the current room temperature the red operation indicator will illuminate and the heater will begin to heat the room If the selected temperature is less than that of the current room temperature the red operation indicator will go out and the heater will go into a standby state until the room t...

Page 9: ...t the heater is now in delay off timer operation If the selected temperature is above that of the current room temperature the red operation indicator will illuminate and the heater will begin to heat the room If the selected temperature is less than that of the current room temperature the red operation indicator will go out and the heater will go into a standby state until the room temperature h...

Page 10: ...neously until the padlock symbol is displayed All control functions are now locked and none of the buttons on the control will work To Deactivate the Lock To deactivate the lock repeat locking step above to return to normal operation TILT SWITCH As a safety feature this heater is fitted with a tilt switch that automatically places the heater into standby mode if the appliance tilts more than 45 an...

Page 11: ...apability If a fault occurs an Error Code will flash on the two digits of Digital LED display a repeating chime will also sound and the appliance will be prevented from operating Please quote the error code displayed when enquiring about service for example Error Code E 0 Temperature sensor disconnection SERVICE AND REPAIR If the electric power cord or plug are damaged they must be replaced by Rin...

Page 12: ... the brackets are level and the minimum clearances as described above are observed This heater MUST NOT be located immediately below a socket outlet This heater MUST be positioned within one metre of a socket outlet to ensure the flexible cord and plug can reach it This heater is NOT designed to be built in DO NOT attach the castors to the heater base for wall installations The heater is suitable ...

Page 13: ...r is now ready to be used as a free standing appliance Refer to the operation section at the front of this manual for full instructions on how to use the heater 5 Remove the cable tie from the flexible cord then insert the power plug of the heater directly into a power socket outlet DO NOT bundle or coil the flexible cord to reduce it s length as overheating and subsequent fire hazard could result...

Page 14: ...or foot with the two holes in the base the appliance and fix in place with the screws removed in step 4 6 Repeat steps 4 and 5 to install the second castor assembly 8 The heater is now ready to be used as a free standing appliance Refer to the operation section at the front of this manual for full instructions on how to use the heater 7 Rotate the heater back to the upright position and remove the...

Page 15: ...Rinnai 15 DEPH_OIM NOTES ...

Page 16: ...rvice please call our National Help Line Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales and Service National Phone 1300 555 545 Fax 1300 555 655 Technical Helpline and Spare Parts National Mon Fri 8am 5 30pm EST Phone 1300 555 545 Fax 1300 300 141 Cost of a local call higher from mobile or public phones E mail enquiry rinnai com au For further ...

Reviews: