Rinnai DDSTAT controller programming guide: 12697-C 03-20 |
5
Basic operation - setting tank temperatures
Once the controller has power, the tank temperature (home) screen is displayed. If the temperature
probe is in place a reading will be displayed. If you need to change the default tank temperatures
follow the below steps.
TANK SET
65
ACCEPT
TEMPERATURE
1
2
3
4
5
1
2
3
Press SET
Press SET to allow the tank settings to be
changed.
Change the tank set temperature
Default is 65 °C, to change use buttons 4
and 5, and press ACCEPT (button 2).
TANK LOW LIMIT
60
ACCEPT
TEMPERATURE
1
2
3
4
5
Change the low limit temperature
Default is 60 °C, 5 °C less than the tank
set temperature. To change use buttons 4
and 5, and press ACCEPT (button 2).
TANK TEMPERATURE 62
SET
INFO
MAINT
PUMP AUTO
1
2
3
4
5