Model 2424WC
800-621-9419
3 5
INSTALLER’S INSTALLATION INSTRUCTIONS
Remote Controls - Installation
TERMINAL
CLAMP
1)
Determine a suitable location for the
control.
2)
Make three holes on the wall as shown.
3)
Run the cable between the control and
the Continuum 2424WC or the control
and the other control.
4)
Remove the face plate from the remote control, using a screw driver.
5)
Connect the cable to the remote control.
6)
Mount the control to the wall using the holes drilled in step 2.
Note: If the cable cannot be run in the wall cavity, the plastic knockout should be re-
moved from the top or bottom of the control to allow flush mounting with the wall
7)
Disconnect the power from the Continuum 2424WC.
8)
Remove the cover of the Continuum 2424WC.
9)
Remove the plastic cover from the PCB and electrical connections.
DO NOT ATTEMPT TO CONNECT THE REMOTE CON-
TROLS WITH THE POWER ON, THERE'S 120 VOLT PO-
TENTIAL, NEXT TO THE REMOTE CONTROL CONNEC-
TIONS INSIDE THE UNIT. All service and wiring should be
performed by a certified installer.
10) Thread the cable through the access hole at the
base of the unit and connect the wires to the con-
trol terminals on the right hand side bottom of the
PCB.
Note: Connect remote control cable to
location labeled “TERMINAL” in the drawing at
right.
11) Secure the control cable using the clamp provided.
12) Replace plastic cover over PCB and then replace
the cover of the Continuum 2424WC.
Note: Remote Control Dimensions are:
4 3/4” H x 4 3/4 W” x 1” D
securing screw
securing screw
wire hole
(21/32” dia.)
outline of remote
3 1/4”
1 1/16”
Summary of Contents for CONTINUUM 2424WC
Page 23: ...Model 2424WC 800 621 9419 2 3 RECOMMENDED PIPING FOR INSTALLATION ...
Page 31: ...Model 2424WC 800 621 9419 3 1 INSTALLER S INSTALLATION INSTRUCTIONS Wiring Diagram ...
Page 32: ...Model 2424WC www rinnaiamerica com 3 2 INSTALLER S INSTALLATION INSTRUCTIONS Wiring Diagram ...
Page 39: ...Model 2424WC 800 621 9419 3 9 INSTALLER S INSTALLATION INSTRUCTIONS Exploded View Cabinet ...
Page 41: ...Model 2424WC 800 621 9419 4 1 INSTALLER S INSTALLATION INSTRUCTIONS Exploded View Internals ...